Gpi i/o, Joystick tilt zoom lever focus dial, Setting tally mode – Sony WI-1000XM2 Noise-Canceling Wireless In-Ear Headphones (Black) User Manual

Page 52: Command sel camera link

background image

52

JOYSTICK TILT

ZOOM LEVER

FOCUS DIAL

GPI I/O

Sets the GPI I/O connector signal format and tally
operation mode.

SETTING

TALLY MODE

This setting is enabled when SETTING is set to INPUT.

COMMAND SEL

CAMERA LINK

Tally lamp control operation

Settings (Bold:
default value)

Description

STANDARD

Inclining the joystick forward tilts the
camera up. Inclining rearward tilts the
camera down.

REVERSE

Inclining the joystick forward tilts the
camera down. Inclining rearward tilts
the camera up.

Settings (Bold:
default value)

Description

STANDARD

Moving the ZOOM lever to the W side
(Wide) zooms out, and moving to the T
side (Tele) zooms in.

REVERSE

Moving the ZOOM lever to the W side
(Wide) zooms in, and moving to the T
side (Tele) zooms out.

Settings (Bold:
default value)

Description

STANDARD

Turning the FOCUS knob clockwise
moves the focus in the Far direction,
and turning counterclockwise moves
the focus in the Near direction.

REVERSE

Turning the FOCUS knob clockwise
moves the focus in the Near direction,
and turning counterclockwise moves
the focus in the Far direction.

Settings (Bold:
default value)

Description

INPUT

Sets the control signal direction of the
GPI I/O connector to INPUT. In this
case, connect a tally control input
signal to the connector.

OUTPUT

Sets the control signal direction of the
GPI I/O connector to OUTPUT. In this
case, the connector functions as a
contact output connector which
outputs the camera number of the
target camera.

Settings (Bold:
default value)

Description

NORMAL

Displays the tally input lamp
corresponding to the number of the
camera with tally input ON, and
automatically selects the camera as the
target camera.

ON AIR

Displays the tally input lamp
corresponding to the number of the
camera with tally input ON.

Settings (Bold:
default value)

Description

STANDARD

Sets the input/output method to
STANDARD method. The camera
numbers and input/output pin numbers
have a 1:1 correspondence.

If the unit and cameras are
connected by serial connection,
cameras 1 to 7 correspond to input/
outputs 1 to 7.

If the unit and cameras are
connected by LAN connection,
cameras 1 to 10 in group 1
correspond to input/outputs 1 to 10.

EXPAND

Handles camera numbers as binary
numbers.

Tally input numbers 8 and higher in
a serial connection are ignored. In
this case, the response is equivalent
to no input.

Numbers in a LAN connection,
corresponding to cameras 1 to 10 in
groups 1 to 10, are handled as the
numbers 1 to 100. Tally input
numbers 101 and higher are
ignored. In this case, the response is
equivalent to no input.

Settings (Bold:
default value)

Description

ON

, OFF

Turns tally lamp control on/off. The
tally lamp control operation varies
depending on the combination of the
SETTING and CAMERA LINK
settings. For details, see “Tally lamp
control operation”
below.

Tally lamp

Tally input lamps