Welltech SIPIVR 6800GS V.2.1 User Manual
Page 89

88
Figure 6-5
Next Goto: Next component to be executed
Remark: Description or remark for this component
6.6
Execute Sub-Flow
[Introduction]
This function is used to execute a sub-flow. All variable can be seen in sub
flow. After return from sub-flow by the sub-flow return, the return value can be
used to indicate the execution result.
[Description]
Right-click the Execute Sub-Flow component, the screen appears as
Figure 6-6.
Figure 6-6
Call Flow Name: Sub flow name to be called
Return Value: Sub flow return value
Not Found Goto: Next component to be executed if the sub-flow is not
found
Next Goto: Next component to be executed if the operation is successful
Remark: Description or remark for this component
6.7
Sub-Flow Return
[Introduction]
This component is used together with Execute Sub-Flow as a pair, to quit
the sub-flow and go back to the upper (calling) call flow.
[Description]
Right-click the Sub-Flow Return component, the screen appears as
Figure 6-7.