Cpu leds – Sierra Video Ponderosa 3G Series Routing Switcher Family with MediaNav User Manual
Page 25

PONDEROSA
19
DIP Switch Settings Cont.
CPU LEDs
There are 31 LEDS controlled by the Ponderosa Control Card. They are located as
follows:
Three LEDs are located on the front edge of the CPU board. They are labeled from top to
bottom
LED 6, LED 7, and LED 8.
Label
Name
Color
Function
LED 6
MASTER
Yellow
If in a redundant system (DIP SW1 on), LED
is on if running as master. If not redundant,
always on.
LED 7
POWER
Green
Indicates power is okay.
LED 8
ERROR
Red
On if an error in the system is detected (See
Note below)
Note:
The errors that will cause the Error LED to come on are dependent on the system configured.
1. There is no crosspoint board in the system.
2. A power supply is present but off.
3. A power supply is present and its fans are off.
DIP
Switch
Action
S1
Default
1
REDUNDANT CPU
On when in a redundant system
OFF
2
MASTER CPU
Ignored when SW1 is off. Otherwise, on if this board is set to
be the master
OFF
3
Not currently used. Should always be off
OFF
4
FACTORY DEFAULT
On when reverting the card to factory defaults. This may
cause the system to reboot. No changes to the network
settings will be allowed when this switch is on. Other
configuration settings will result in an error.
OFF
5
Not currently used. Should always be off
OFF
6
DISABLE STANDBY TAKEOVER
For internal use only. Customers should always have this set
to off.
Used when debugging a redundant system
7
NETWORK ADDRESS
On when reverting the network configuration to defaults. This
may cause the system to reboot. No changes to the network
settings will be allowed when this switch is on.
OFF
8
Not currently used. Should always be off
OFF