Cpu leds – Sierra Video Ponderosa 3G Series Routing Switcher Family with MediaNav User Manual

Page 25

background image

PONDEROSA

19

DIP Switch Settings Cont.

CPU LEDs

There are 31 LEDS controlled by the Ponderosa Control Card. They are located as
follows:

Three LEDs are located on the front edge of the CPU board. They are labeled from top to
bottom
LED 6, LED 7, and LED 8.

Label

Name

Color

Function

LED 6

MASTER

Yellow

If in a redundant system (DIP SW1 on), LED
is on if running as master. If not redundant,
always on.

LED 7

POWER

Green

Indicates power is okay.

LED 8

ERROR

Red

On if an error in the system is detected (See
Note below)

Note:

The errors that will cause the Error LED to come on are dependent on the system configured.

1. There is no crosspoint board in the system.
2. A power supply is present but off.
3. A power supply is present and its fans are off.

DIP

Switch

Action

S1

Default

1

REDUNDANT CPU
On when in a redundant system

OFF

2

MASTER CPU
Ignored when SW1 is off. Otherwise, on if this board is set to
be the master

OFF

3

Not currently used. Should always be off

OFF

4

FACTORY DEFAULT
On when reverting the card to factory defaults. This may
cause the system to reboot. No changes to the network
settings will be allowed when this switch is on. Other
configuration settings will result in an error.

OFF

5

Not currently used. Should always be off

OFF

6

DISABLE STANDBY TAKEOVER
For internal use only. Customers should always have this set
to off.
Used when debugging a redundant system

7

NETWORK ADDRESS
On when reverting the network configuration to defaults. This
may cause the system to reboot. No changes to the network
settings will be allowed when this switch is on.

OFF

8

Not currently used. Should always be off

OFF