Display all alarms, Display all alarms -6 – Quintum Technologies Tenor AS User Manual
Page 71
![background image](https://www.manualsdir.com/files/801753/content/doc071.png)
5-6
P/N 480-0059-00-10
Chapter 5: Advanced Topic: Diagnostics/Maintenance
Display all Alarms
You are able to display both active alarms and an alarm history as follows:
1. Through CLI, access the Monitor prompt.
2. Type alarm. Both active alarms and the alarm history will be displayed. See section
for field definitions.
Figure 5-1 Alarm sample
Minor
Log RADIUS server error
Displayed when the RADIUS server fails to send
required data or the data sent by the RADIUS
server has improper values. Incorrect information
may contain the following:
RADIUS Server: Credit amount (-1)
RADIUS Server: Credit minus amount
RADIUS Server: Not supported currency
RADIUS Server: Credit time (-1)
RADIUS Server: Credit time < 6 sec
RADIUS Server: Invalid error code
Informational
Gatekeeper status
Reports the status of the Gatekeeper.
Informational
Miscellaneous information
Miscellaneous information about the unit is
reported. The contents of this alarm will vary.
Informational
Info Software Error
Indicates information about miscellaneous soft-
ware error. This does not affect system operation.
Informational
Glare occurred
An incoming and outgoing call went through at the
same time, and the remote end call did not back off,
but the situation was corrected.
Severity
(appears as
part of severity
field)
Alarm Description
(text appears in desc field)
Definition
IP# Sequence#Type#Severity# Desc# Slot# Device# Analog Interface# Channel# Date/Time
192.166.28.230:944:ALR:3:Border Element connection lost:0:0:0:0:TUE OCT 14 14:05:27 2003
192.166.28.230:946:RPT:4:Gatekeeper status (Gatekeeper(0.0.0.0) removed):0:0:0:0:TUE OCT 14
14:05:27 2003