5-6

P/N 480-0059-00-10

Chapter 5: Advanced Topic: Diagnostics/Maintenance

Display all Alarms

You are able to display both active alarms and an alarm history as follows:

1. Through CLI, access the Monitor prompt.

2. Type alarm. Both active alarms and the alarm history will be displayed. See section

How to Read

Alarms

for field definitions.

Figure 5-1 Alarm sample

Minor

Log RADIUS server error

Displayed when the RADIUS server fails to send
required data or the data sent by the RADIUS
server has improper values. Incorrect information
may contain the following:

RADIUS Server: Credit amount (-1)
RADIUS Server: Credit minus amount
RADIUS Server: Not supported currency
RADIUS Server: Credit time (-1)
RADIUS Server: Credit time < 6 sec
RADIUS Server: Invalid error code

Informational

Gatekeeper status

Reports the status of the Gatekeeper.

Informational

Miscellaneous information

Miscellaneous information about the unit is
reported. The contents of this alarm will vary.

Informational

Info Software Error

Indicates information about miscellaneous soft-
ware error. This does not affect system operation.

Informational

Glare occurred

An incoming and outgoing call went through at the
same time, and the remote end call did not back off,
but the situation was corrected.

Severity

(appears as

part of severity

field)

Alarm Description

(text appears in desc field)

Definition

IP# Sequence#Type#Severity# Desc# Slot# Device# Analog Interface# Channel# Date/Time

192.166.28.230:944:ALR:3:Border Element connection lost:0:0:0:0:TUE OCT 14 14:05:27 2003

192.166.28.230:946:RPT:4:Gatekeeper status (Gatekeeper(0.0.0.0) removed):0:0:0:0:TUE OCT 14
14:05:27 2003