3. Ground the generators.

4. Start both generators and confirm that both green "RUN" lights are illuminated.

The Smart-throttle system may be used as long as the Smart-throttle setting of

both generators is the same.

5. Securely plug the electrical appliance plug into parallel cable receptacle and

switch on the electrical appliance power supply.

6. Do not use the receptacle on the control panel of the generator. While operating

in parallel, the only AC output is through the receptacle on the parallel cable box.

The required output of the electrical appliance cannot exceed the rated output of

parallel generators.

Shutting off the generators:

1. Turn off the electrical appliance, then pull out the receptacle plug.

2. Turn off the two generators.
3. Disconnect the parallel kits from the generators.

n

The parallel cable connectors can only be used with MMD PowerPro Parallel

Power Ready generators (IGR1000P, IGR2000P, and IGR2600HP).

n

While connecting the generator and electrical appliance with the parallel output

cable, carefully and safely insert the plug into the receptacle.

n

Do not use the receptacles on the control panel of either generator while

operating in parallel. The only AC output is through the receptacle on the parallel

cable box.

n

Do not disconnect the parallel cables during operation.

IGR1000P

IGR2000P

IGR2600HP

PARALLEL
OUTPUT
RECEPTACLES

PARALLEL OUTPUT
RECEPTACLES

PARALLEL OUTPUT
RECEPTACLES