background image

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (041715)

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (041715)

Page 18

Page 19

STARTER GRIP

4. Move the choke lever to the RUN position after the engine warms up.

CHOKE LEVER

RUN

RUN

n

If the engine stops and will not restart, check the engine oil level before further

troubleshooting.

STOPPING THE ENGINE

1. Switch off the connected equipment and disconnect from the generator.

2. Turn off the engine switch.
EMERGENCY STOP

Turn the start switch to the OFF position.

Continually stopping the generator with a load applied can lead to damage of the

control module.

GROUND TERMINAL

GROUND
MARK

6. Generator Use

Be sure to ground the generator when loads are connected.

n

To prevent electrical shock from faulty appliances, the generator should be

grounded. Connect a length of heavy cable between the generator's ground

terminal and an external ground source.

n

Connections for standby power to a building's electrical system must be made

by a qualified electrician and must comply with all applicable laws and electrical

codes. Improper connections can allow electrical current from the generator to

back feed into the utility lines. Such back feed may electrocute utility company

workers or others who contact the lines during a power outage. When utility

power is restored the generator may explode, burn, or cause fires in the

building's electrical system.

n

Do not connect the generator to an automatic transfer device. Severe damage to

the inverter module may result.

3. Pull the starter grip until resistance is felt then pull the starter grip briskly

toward the arrow as shown below.

n

Do not allow the starter grip to

snap back. Return it slowly by hand.

n

Do not let the starter rope rub

against the generator body or the

rope will wear out prematurely.