Generator use – MMD Equipment IGR1000 User Manual
Page 10

MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (041715)
MMD PowerPro Inverter Generators • IGR1000P • IGR2000P • IGR2600HP (041715)
Page 18
Page 19
STARTER GRIP
4. Move the choke lever to the RUN position after the engine warms up.
CHOKE LEVER
RUN
RUN
n
If the engine stops and will not restart, check the engine oil level before further
troubleshooting.
STOPPING THE ENGINE
1. Switch off the connected equipment and disconnect from the generator.
2. Turn off the engine switch.
EMERGENCY STOP
Turn the start switch to the OFF position.
Continually stopping the generator with a load applied can lead to damage of the
control module.
GROUND TERMINAL
GROUND
MARK
6. Generator Use
Be sure to ground the generator when loads are connected.
n
To prevent electrical shock from faulty appliances, the generator should be
grounded. Connect a length of heavy cable between the generator's ground
terminal and an external ground source.
n
Connections for standby power to a building's electrical system must be made
by a qualified electrician and must comply with all applicable laws and electrical
codes. Improper connections can allow electrical current from the generator to
back feed into the utility lines. Such back feed may electrocute utility company
workers or others who contact the lines during a power outage. When utility
power is restored the generator may explode, burn, or cause fires in the
building's electrical system.
n
Do not connect the generator to an automatic transfer device. Severe damage to
the inverter module may result.
3. Pull the starter grip until resistance is felt then pull the starter grip briskly
toward the arrow as shown below.
n
Do not allow the starter grip to
snap back. Return it slowly by hand.
n
Do not let the starter rope rub
against the generator body or the
rope will wear out prematurely.