If contact is made with skin, flush with water immediately.
n
If contact is made in eyes, flush with water immediately for at least 15 minutes
and contact a physician.
n
Battery contents are poisonous — If swallowed, drink large quantities of water or
milk and follow with milk of magnesia or vegetable oil and call a physician.
n
KEEP OUT OF REACH OF CHILDREN.
2. Start the engine
n
The DC receptacle may be used while the AC power is in use.
n
The DC receptacle is protected from an overload with a fuse. If the DC circuit is
overloaded, the 5 amp fuse will blow and power to the DC receptacle will cease.
The red light on the DC panel will illuminate. The fuse is located to the left of the
receptacle and is accessed by snapping open the access door. Replace the fuse
with one of the same capacity. Using a higher rated fuse may cause damage to
the generator alternator.
FUSE
DC RECEPTACLE
LOW OIL ALARM
INDICATOR LIGHT
(RED)
Air Conditioning Operation
n
When running in parallel (see Section 8) the combination of an IGR1000P and
either an IGR2000P or IGR2600HP model can start and run most 13,500 BTU
air conditioners. An IGR2000P and an IGR2600HP or two IGR2600HP models
will start and run most 15,000 BTU units.
n
For best results, the SMART throttle switches should be in the off position.
n
Bring the generators to normal operating temperatures before applying the air
conditioning load. Always allow a 2 minute wait period when manually cycling an
air conditioner off and on.
n
A longer wait period may be required under unusually hot weather conditions.
n
Additionally, all other loads should be turned off until the air conditioner has
started and is performing normally. It is also important to follow the air conditioner
manufacturer's instructions for starting and restarting for proper operation.
n
Some air conditioner manufacturers offer a start capacitor or rapid start kit. The
lack of a start capacitor can cause the air conditioner to draw too high a starting
current and overload the generators. Contact your air conditioner dealer if you
consistently have problems starting your air conditioner with the generators in
parallel.
Low oil alarm system
The low oil alarm system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase falls
below a safe limit, the low oil alarm system will automatically shut down the engine
(the engine switch will still remain in the ON position).
If the low oil alarm system shuts down the engine, the low oil alarm indicator light
(red) will come on when you operate the starter and the engine will not run. If this
occurs, search for any oil leaks, and add oil to engine to resume normal operation.