Digital Alert Systems DASDEC-II MANUAL User Manual
Page 69

Digital Alert Systems: DASDEC User Manual
63
Forward audio message in decoded Weekly Tests 
If a decoded Required Weekly Test (RWT) has audio, it will be forwarded. This is uncommon, but can 
occur. When disabled, decoded RWT alerts with audio will discard the audio portion of the RWT during 
forwarding. 
 
Segmented Manual Alert Forwarding 
If Enabled, manual forwarding will provide buttons to send the alert header and attention signal 
separately from audio and EOM. This provides an opportunity to dub in live audio. Uncheck to disable 
Segmented Manual Alert Forwarding. 
 
Block Auto-Forward of non-originated EAS_NET decoded Weekly Tests (RWT) 
All RWTs from EAS NET senders are subjected to Auto-Forward filters. 
 
Block Auto-Forward of CAP decoded Weekly Tests (RWT) 
All RWTs from CAP servers are subjected to Auto-Forward filters. 
 
Force Auto-Forward Monthly Tests within an hour 
This option will force Auto-Forward monthly tests within an hour. If you do not want this to happen, 
leave it as disabled. 
 
Override Decoded Audio portion for Monthly Tests 
This option displays three extra audio file selectors to pick pre-recorded audio for pre-alert, post-alert 
and override of the original decoded voice audio message portion of a Monthly Test alert. Defaults to 
disabled, check to enable. 
 
2. Forwarding Serial Protocol
This hyperlink displays the current serial protocol(s) selected during forwarding. Click the link to go to 
the Setup > Video/CG > Main Serial CG Options page to review and/or change the serial protocol(s). 
3. Configure Auto or Manual Forwarding Operation
One of the essential decisions that an EAS participant must make is whether to run an EAS decoder in 
Auto-forwarding mode or in Manual forwarding mode. This section of options provides the controls over 
these two basic options. 
 
The text box on the left side of this section will indicate the current forwarding state. It will display either 
"Auto-Forward Mode is Enabled" or "Manual Forward Mode is Enabled." The same information is also 
prominently displayed on the Decoder > Incoming Alerts pages. To set the Auto-Forward Mode or the 
Manual Forward Mode look to the checkbox to on the right side of this section. 
 
Auto-Forward Mode checkbox: Check (enable) the first toggle box on the right side of this section to 
select Alert Auto-Forwarding. Uncheck to select Manual Alert Forwarding. The toggle box will display a 
standard label that says if Auto-Forward Mode is Enabled or Disabled and which mode is currently 
selected. 
 
When Manual forwarding is set, a user of the DASDEC II must use the Web Interface or use GPI input 
contact closures to actively forward any unforwarded alerts from the Decoder > Incoming/Decoded 
Alerts Active Decoded list display. 
 
During Auto-Forward mode, the DASDEC II forwards alerts without review or intervention provided they 
pass the currently configured Auto-Forwarding criteria. 
 
NOTE: Emergency National Activation (EAN) and Termination (EAT) alerts always 
forward automatically. 