outputs to be assigned to different stations and thereby recognized as triggering an action because a 
specific station is active. Configure per station used GPIO output relays on the proper station interface 
configuration page under Setup > Decoder > Forwarding. 
GPIO Input 1 alert programming
A selection menu allows GPIO Input #1 to be programmed to do: 
1. Nothing; 
2. Forward an active unforwarded decoded alert upon closure; (Requires Plus Package license) 
3. Hold a non-national alert when forwarded or originated until closure; (Requires Plus Package license) 
4. Delay a non-national alert while closed. 
GPI Input 2 alert programming
A selection menu allows GPIO Input #2 can be programmed to do: 
1. Nothing; 
2. Issue a Required Weekly Test alert (RWT). The FIPS codes used are the same as those used for the 
normal One-Button test. 
3. Start voice dub EAS alert on closure; subsequent closures skip to EOM. (Requires Plus Package 
license) 
GPIO Output 1 Relay programming (Programmability requires Plus Packagelicense)
This selection box allows for programming the GPI Output #1 closure. Set according to the condition 
that needs to be monitored. 
 
GPIO Output #1 can be programmed to make a contact closure during: 
 1. EAS audio play-out. 
 2. Momentary closure at start of EAS Audio play-out. 
 3. Momentary closure at end of EAS Audio play-out. 
 4. Momentary closure at start and end of EAS Audio play-out. 
 5. EAS Video play-out. 
 
GPIO Output 1 Activation Filter Configuration 
Choose the FIPS and EAS codes that will control which alerts trigger the applicable programmed GPIO 
output 1 relay. 
GPI Output 2 Relay programming
This selection box allows for programming the GPI Output #2 closure. Set according to the condition 
that needs to be monitored. 
 
 
 
 
 
 
 
 