Digital Alert Systems DASDEC-II MANUAL User Manual
Page 65

Digital Alert Systems: DASDEC User Manual
59
 
Draw Mode – Controls the appearance of the crawl displayed on the screen. Choose between a White 
Character/Clear Background, White Character / Black Background, White Character / Half-tone 
Background, or Black Character / White background. 
 
Serial Point Flow Control – Select Hardware or Software or None depending upon the hardware 
support on the remote device. 
 
Iterations – Defaults to one. Crawl is done once. Set from 1 to 5. 
 
Repeat Alert Video Display – Defaults to Do Not Repeat 
Select from a set of options for repeating the data write to the remote device after a pause period set 
from the Set Alert Video Repetition Period field. The repeat period has to be at least 2 minutes. 
10. BetaBrite LED Sign Attribute Settings
Immediate display upon matching decoded alert defaults to disabled. When enabled, matching FIPS 
and EAS filtered alerts are crawled on the BetaBrite LED display upon decoding. When disabled, 
matching FIPS and EAS filtered alerts are displayed upon origination and forwarding play-out. Use this 
feature as a way to post a visual notification that an alert has been decoded. 
 
Display Duration Control The duration of the BetaBrite crawl is set by selecting one of three Display 
Duration Control radio button options. The duration can be set to the full alert duration, to the alert audio 
duration, or to a custom duration. 
 
There is a button to test the BetaBrite display, and one to stop the test. The test consists of crawling the 
date and time for about 30 seconds. 
 
11. Monroe Envoy
No attributes to set. This is only available on the Main Serial port.
12. BDI GPM-300 Matrix Switcher
Audio Channel Selections – switch these GPM300 channels to EAS during alert audio.
4.7.4 Video
Out
The Video Output Configuration sub-page has three toggle boxes: Video Output, Serial controlled video duration, 
and English to Spanish EAS Translation. DASDEC II-1EN can generate video output for originated and 
forwarded alerts. When video output is generated, a set of details pages will be played out of the RCA video 
output port on the back of the DASDEC II. 
 
Click
to apply changes to this page.
1. Video Output upon Alert Origination/Forwarding.
Use the checkbox to Enable or Disable the base station Video Output If licensed and the hardware support 
is enabled; a DASDEC II can provide a full screen NTSC analog video display of the current originated or 
forwarded alert. 
 
Multistation mode note: When DASDEC II multistation mode is enabled, the Video Output toggle for each 
NOTE: In current software, running the NTSC video details generator will slow down the 
start of every alert by a few seconds as the video system is initialized from a VGA 
console state to a video output state. Depending on the required timing of your on-air 
system, this can be objectionable. Only enable DASDEC II NTSC video details output if it 
is needed. 