beautypg.com

Leslie Controls CONTROL VALVES DLOS-2 & DDLOS-2 (150/300) User Manual

Page 9

background image

9

10.

Examine gasket. Replace seal if necessary

to obtain an air-tight seal.

11.

Clean all metal parts. Remove any rust, dirt

or sharp edges that might damage stem seal.

12.

Lubricate spring washer(s) (33 & 34), spring

adjustor (35) and actuator stem threads with

anti-seize compound.


REASSEMBLY

1.

55R & 85R – Place the new stem seal in

position and install the seal ring with the lip

upward. Tighten screws. Press stem seal

down until flush with spacer, install lower

diaphragm case and tighten nuts.

2.

When reassembling, place a block under the

actuator stem to hold the stem high enough

so that clearance between the stem seal bead

and the groove is not greater than 1/8 inch.

Line up the actuator stem in the center of the

opening in the lower diaphragm case so that

the stem seal bead will enter the groove in

the stem collar when the lock nut is

tightened.

3.

Place the stem collar over the actuator stem

with the groove upward followed by the

diaphragm and the diaphragm disc. Be sure

that the center hole in the diaphragm fits

properly over the raised lip of the collar.

4.

Install the lock nut and tighten. REMOVE

THE LOCK ROD.

5.

Install the upper diaphragm case and Hand

Operating Device (if fitted) to actuator and

tighten the nuts and bolts.


ALL ACTUATORS

Reset valve for proper travel and spring preload

as previously described, by compressing actuator

adjusting spring(s) sufficiently to move

diaphragm(s) up against actuator stop. Align

travel indicator plate and tighten screws. Plate

scale indicates rated valve travel.

This manual is related to the following products: