Leslie Controls AEROFLOW SUPPLEMENT Thermal Growth 2 Aero TECO User Manual
Leslie Controls Equipment
12501 Telecom Drive, Tampa Florida 33637
Installation, Operating and
Maintenance Instructions
Supplement
10/2.5.1.E
Rev. 0
AEROFLOW SUPPLEMENT
Special Thermal Growth Trim 2”Aeroflow for
TECO
TABLE OF CONTENTS
TABLE OF CONTENTS ............................................................................................................................. 1
ILLUSTRATION INDEX............................................................................................................................ 1
INSTALLATION ......................................................................................................................................... 1
MAINTENANCE ......................................................................................................................................... 1
ILLUSTRATION INDEX
F
IGURE
1
-
2”
A
EROFLOW WITH SPECIAL THERMAL GROWTH TRIM
................................................................. 2
INSTALLATION
NOTE: Refer to Fig. 1 for installation.
1.
Install seat gasket (507) into valve body
(306).
2.
Install seat (506), cage (600), body gasket
(305) into valve body (306).
3.
Slide the valve plug/stem assembly (505)
into the cage (600) slowly.
4.
Place the cage load ring (508) centered on
the top of the cage.
5.
Complete the bonnet (302) installation as
stated in the valve IOM being careful to
insure alignment of the cage load ring with
the recess in the bonnet.
MAINTENANCE
1.
During routine maintenance the trim should
be carefully inspected for wear and replaced
as needed.
2.
The valve IOM should be followed for all
operating and maintenance procedures.
CAUTION!
All warnings from valve IOM must be followed.