Set Operation Parameters
31
•
Enter a station ID (1 to 254) for multi-drop network configuration
•
Enter 255 for single station remote control
Parameter 28 TX2 Format (2 Condec format)
Serial Port 2 can be used for continuous transmission of scale data. The TX2 Format
parameter determines what is sent. There are 5 selections:
1 - AND:
Status:
OL (overload), ST (stable), US (unstable, in motion)
Mode:
GS (gross mode), NT (net mode)
Polarity:
+ (positive weight), - (negative weight)
Weight:
7 characters data, NOT zero blanked, with decimal point
Units:
lb, kg, t (ton), tn (tonne), g
Terminate:
lf, cr (line feed, carriage return)
2 - CONDEC:
Polarity:
space (positive weight), - (negative weight)
Weight:
7 characters, zero blanked, with decimal point
Units:
L (lb), K (kg), T (ton), G (gram), O (oz)
Mode:
G (gross mode), N (net mode)
Status:
Terminate:
lf, cr (line feed, carriage return)
3 - WEIGHTRONIX:
Mode1:
space (gross mode), 0 (zero if net mode)
Mode2:
G (gross mode), N (net mode)
Polarity:
+ (positive weight), - (negative weight)
Weight:
6 characters, NOT zero blanked, with decimal point
Units:
lb, kg, oz, g
Terminate:
lf, cr (line feed, carriage return)
4 - OHAS:
Polarity:
space (positive weight), - (negative weight)
Weight:
7 digits, zero blanked, with decimal point
Units:
lb, kg, oz, g
Mode:
G (gross mode), N (net mode)
Status:
Terminate:
lf, cr (line feed, carriage return)
5 - Print label 85: transmits the contents of parameter 85 (print label 85)
Data entered into a print label can include register data:
[253] [reg no] buffer register data, minimum size (zero blanked no spaces)
[254] [reg no] buffer data, 7 character field, zero blanked, right justified.