7 peak hold function – Industrial Data Systems IDS 440 User Manual
Page 24

IDS440 Users Manual version 4.2
Built In Application Programs
20
enter a new value and then press the ENTER key. The next sequence number printed
will be the entered value +1.
Notes
• The ID file maintenance functions are password level 1 protected. If a password has
been configured (function 64) the operator will be prompted for the password before
the file maintenance menu is displayed.
• ID memory is cleared to zero at power up unless parameter 41 (battery back up
enable) is set to 1.
# 7 Peak Hold Function
The peak hold register maintains the peak weight detected by the weight indicator.
Enable Peak Hold
Access configuration parameter 75. Enter a 1 to enable peak hold, enter a 0 to disable
peak hold.
Clear Peak Hold Register
Press the CLEAR key to reset the peak hold register to 0.
Use the Scale Basic built in function Clear Peak [143] to reset the peak hold register.
Display Peak Weight
Use the GROSS/NET key to scroll thru the display options as follows:
Initial mode:
Display gross weight.
Gross LED on.
First GROSS/NET press: Display net weight.
Net LED on.
Next GROSS/NET press: Display gross peak weight. Gross LED flashing.
Next GROSS/NET press: Display net peak weight.
Net LED flashing.
Next GROSS/NET press: Display gross weight.
Gross LED on.
Etc.
Print Peak Weight
Use function 65 (Configure Print Formats) to format the print output using:
Print Item 19:
print Gross Peak weight.
Print Item 20:
print Net Peak weight.