beautypg.com

9 brake chopper, 10 control interface [x1, Brake chopper – Festo Контроллеры двигателя CMMS-ST User Manual

Page 41: Control interface [x1

background image

3. Product description

Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH

41

speed and position for EMMS-ST series motors. The actual speed is determined based on
the measured rotor position. The rotor position is smoothed via a configurable PT

1

filter.

The position counter for positioning has a data width of 32 bits. The position within a
motor rotation is resolved to max. 16 bits. This results in a maximum possible positioning
range of ±32767 rotations.

3.3.9 Brake chopper

A brake chopper with a braking resistor is integrated in the power output stage. If the
permitted load capacity of the intermediate circuit is exceeded during the energy
recovery, the braking energy may be converted to heat by the internal braking resistor.
The brake chopper is actuated with software control. The internal braking resistor is
protected against overloading via software and hardware.

Note

If the maximum braking energy of the braking resistor is exceeded,
the message “070 – Overvoltage in intermediate circuit” is output
and the end stages switched off.

3.3.10 Control interface [X1]

The control interface [X1] is designed as D-Sub 25-pin. The following signals are available:

Pin Name Mode 0

(DIN12=0)

Mode 1
(DIN12=1)

Mode 2
(DIN9=1 &
DIN12=0)

Mode 3
(DIN9=1 &
DIN12=1)

1

AGND

Screen for analogue signals

14 AGND Reference potential for

analogue signals

2 AIN0

DIN12

Setpoint input 0
Mode switchover

"1"

"0"

"1" slave synch.

15 #AIN0

DIN13


Stop input (low active)

STOP STOP STOP

3

DIN10

Record selection 4
(high active)

Jog +

Next 1

-

16 DIN11

Record selection 5
(high active)

Jog -

Next 2

-

4

+VREF

Reference output for setpoint
potentiometer

17 AMON0 Analogue monitor output 0

5 Unassig

ned

Unassigned Unassigned

Unassigned

Unassigned

18 + 24 V

24 V supply carried out