2 increment generator input [x2, Increment generator input [x2, Table – Festo Контроллеры двигателя CMMS-ST User Manual
Page 109: 5 pin allocation: i/o interface [x1] mode 3
6. Electrical installation
Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH
109
Pin
Name
Value
Mode = 3 - Synchronisation
13
DOUT3
24 V 100 mA Output freely programmable - default error (low active)
14
AGND
0 V
Reference potential for the analogue signals
15
DIN13
Stop input (low active)
16 DIN11
17
AMON0
0...10 V ±4% Analogue monitor output 0
18
+ 24 V
24 V 100 mA 24 V supply carried out
19 DIN0
20
DIN2
24 V
Pulse_24 / CW
21
DIN4
End stage enable (high active)
22
DIN6
Limit switch 0
23
DIN8
Start synchronisation
24
DOUT0
24 V 100 mA Ready for operation output (high active)
25
DOUT2
24 V 100 mA Setpoint reached output (high active)
Table
6.5 Pin allocation: I/O interface [X1] Mode 3
6.4.2 Increment generator input [X2]
Pin Name
Value
Specification
1
A+
5 V, Ri = 120 Ohm
Increment generator signal A, positive polarity
2
B+
5 V, Ri = 120 Ohm
Increment generator signal B, positive polarity
3
N+
5 V, Ri = 120 Ohm
Increment generator zero pulse N, positive polarity
4
GND
-
Reference GND for the encoder
5
VCC
+5 V +-5% 100 mA
Auxiliary supply, max. load 100 mA, short-circuit
proof.
6 A-
5 V, Ri = 120 Ohm
Increment generator signal A, negative polarity
7
B-
5 V, Ri = 120 Ohm
Increment generator signal B, negative polarity
8
N-
5 V, Ri = 120 Ohm
Increment generator zero pulse N, negative polarity
9
GND
-
Internal screen for the connecting cable
Table
6.6 Pin allocation: Increment generator input [X2]