beautypg.com

Explanation of led sequence – Power Soak 27746 PS-200 Owner's Manual User Manual

Page 22

background image

18

Authorized Service Agency Section

Hazard to untrained or unauthorized personnel.

The following procedures are provided for use only by
an authorized service agency. No facility owner,
manager, employee or other unauthorized person
should attempt to perform any of these procedures. To
obtain the name of a recommended service agent in
your area, please call the Metcraft, Inc. Power Soak
Service Department at 800-444-9624.

When performing troubleshooting procedures, the
authorized service agency will need to open the Power
Soak system's main electrical enclosure.

Properly close the control panel before reconnecting
the circuits.

Explanation of LED Sequence

To verify the proper operation of the Power Soak system, the operating
logic of the controls should be verified. To verify the logic, the control box
will need to be opened.

The Universal Programming Module (UPM) is mounted to the inside of the
control enclosure cover.

The UPM has six LEDs mounted on its top edge. The meaning of each
LED is as follows, starting from the right-most LED:

#1 -

Power On

#2 -

Error Code

#3 -

Wash Tank Low-level Sensor

#4 -

Wash Tank Upper-level Sensor

#5 -

Sanitizer Tank Low-level Sensor

#6 -

Sanitizer Tank Upper-level Sensor