Overload trips – Power Soak 33019 PS-50 Owners Manual User Manual
Page 19

18
Authorized Service Agency Section
- Continued
Overload trips
Look For
Correction
1 Low voltage to unit Check with Volt meter while running
2 Debris in PUMP intake Clean
3 Debris in IMPELLER Remove PUMP and clean
4 Defective PUMP MOTOR If amp draw is greater than 10% of motor rating
and all of above check out, then replace MOTOR