beautypg.com

Pump does not work – Power Soak 33019 PS-50 Owners Manual User Manual

Page 18

background image

17

Authorized Service Agency Section



Hazard to untrained or unauthorized personnel.

The following procedures are provided for use only by an
authorized service agency. No facility owner, manager,
employee or other unauthorized person should attempt to
perform any of these procedures. To obtain the name of a
recommended service agent in your area, please call the
Metcraft, Inc.

Power Soak

Service Department at 800-444-

9624.




When performing troubleshooting procedures, the authorized
service agency will need to open the

Power Soak

system's

main electrical enclosure.

Properly close the control panel before reconnecting the
circuits.




Refer to the previous checklist under the "Facility Owner /
Manager Section" before proceeding to the following
checklist items:

Pump does not work

Look For

Correction

1 No water in sink

Fill sink with water

2 No incoming power to unit

Reset customer’s breaker in breaker control panel

3 Loose wires

Tighten wires

4 Motor overload tripped

See “Overload trips” (Next Section)