Hw (heating only), W/united technologies 1097 spark ignition system), Specifications magic-pak: hw/hwc – Armstrong World Industries HWC PREMIER 183 User Manual
Page 20: Figure 2-2 connection diagram, Connection diagram
SPECIFICATIONS
Magic-Pak: HW/HWC
2-10
SRM-HW/HWC 2/99
#45008-2
HIGH (BLACK)
64HW
MED (BLUE)
51HW
HIGH (BLACK)
38HW
LOW (RED)
LOW (RED)
26HW
HEATING
HEATING
MODELS
EVAP. MOTOR
SPEED CONNECTIONS
EVAP. MOTOR
SPEED CONNECTIONS
GREEN
M
ORANGE
ORANGE
VOILET
VOILET
RED
BLUE
WHT
RED
BLACK
BLUE
YELLOW
WH
IT
E
GREEN
RED
FLAME ROD
ELECTRODE
4 5 6
3
2
1
R
G
W
C
Y
BLA
C
K
BLA
C
K
BLA
C
K
GAS
VALVE
MANUAL RESET
LIMIT SWITCH
COMBUSTION
BLOWER
BLACK
BLUE
YELLO
W
RED
208 V
RED
BLUE
240 V
CAPACITOR
CAPACITOR
BLOWER
208/230-1-60
POWER SUPPLY
COPPER CONDUCTORS
ONLY
}
THERMOSTAT
}
BLA
C
K
BLA
C
K
RED
YELLOW
RED
BLUE
BLACK
BROWN
CONNECTION DIAGRAM
W
Y
G
R
W
Y
G
R
GND
24V
A
C
UNUSED
HEA
T
COOL
L1
CNB
L
SEE
CHART
FOR WIRING
PRESSURE
SW
IT
CH
AUTO RESET
LIMIT SWITCH
IGNITION
CONTROL
BLOWER
MOTOR
CONNECTOR
BLOCK
WIRE NUT
TERMINAL BLOCK
CIRCUITS ENERGIZED
OPERATING MODE CIRCUIT
HEATING
R-W
COOLING
R-G-Y
FAN
R-G
LINE VOLTAGE-FACTORY
LINE VOLTAGE-FACTORY WHEN USED
LINE VOLTAGE-FIELD
LOW VOLTAGE-FACTORY
LOW VOLTAGE-FIELD
NOTE:
IF ANY OF THE ORIGINAL
WIRES ARE REPLACED, THE
SAME SIZE AND TYPE WIRE
MUST BE USED.
YELLOW
TRANSFORMER
ORANGE
H
1
2
3
4
5
DIAGNOSTICS
The following blower/ignition control board
LED codes will indicate normal or abnormal
operations:
SLOW FLASH
Normal Operation, No
Call for Heat
FAST FLASH
Normal Operation, Call for
Heat
2 FLASH
System Lockout - Failed to
Detect or Sustain Flame
3 FLASH
Pressure Switch Open or
Closed
4 FLASH
High Limit or Rollout
Switch Open
5 FLASH
Flame Sensed and Gas
Valve Not Energized
STEADY
Internal Failure
(Micro-controller Failure;
Self-check)
HW (Heating Only)
(w/United Technologies 1097 Spark Ignition System)
FIGURE 2-2
Connection Diagram