Edit/teach a. 00 * all clear, Slct mode a. 00 * edit/teach, All clear? a. 00 y æ 1 n æ 0 – IAI America RCM-P User Manual
Page 43

35
(2) All
Clear:
The data of all the position numbers is cleared.
The position data table becomes as shown below.
No. Position
Vel
Acc
Dcl
Push
LoTh
Range
Zone +
Zone -
Acc/Dcl
Mode
ABS/INC
Cmnd
Mode
Stop
Mode
0 0.00
125
mm/s
0.20 G
0.20 G
0 %
0 %
0.10 mm
0.00
mm
0.00
mm
0 0 0 0
1 50.00
100
mm/s
0.10 G
0.10 G
0 %
0 %
0.20 mm
0.00
mm
0.00
mm
0 0 0 0
2 80.00
100
mm/s
0.10 G
0.10 G
40 %
0 %
5.00 mm
0.00
mm
0.00
mm
0 0 0 0
3 10.00
20
mm/s
0.20 G
0.20 G
0 %
0 %
0.10 mm
0.00
mm
0.00
mm
0 1 0 0
No. Position
Vel
Acc
Dcl
Push
LoTh
Range
Zone +
Zone -
Acc/Dcl
Mode
ABS/INC
Cmnd
Mode
Stop
Mode
0
*
* mm/s
* G
* G
* %
* %
* mm
* mm
* mm
*
*
*
*
1
*
* mm/s
* G
* G
* %
* %
* mm
* mm
* mm
*
*
*
*
2
*
* mm/s
* G
* G
* %
* %
* mm
* mm
* mm
*
*
*
*
3
*
* mm/s
* G
* G
* %
* %
* mm
* mm
* mm
*
*
*
*
Slct Mode/M2
A. 00
* Edit/Teach
Edit/Teach A.
00
* All Clear
Pressing 1 on the Numeric keys will clear all data and
then, the screen will return to the Edit Screen. To
cancel, press 0.
In either case, the screen will return to the previous
screen.
Edit/Teach A.
00
* All Clear
Slct Mode
A. 00
* Edit/Teach
Press the
key once to return the screen to the
Mode Select Screen.
All Clear?
A. 00
Y
Æ 1 N Æ 0
In the Mode Select Screen, using the keys,
select Edit/Teach and then, press the Return key.
In the Edit/Teach Screen, using the keys,
select All Clear and then, press the Return key.