If while the engine is running, the oil

gets low, it will automatically shut itself

down and will not restart until the oil is

added. If the oil is low before start-up,

the generator will not start until oil is

added.
NOTE: The low oil shutdown mechanism

is very sensitive. You must fill the engine

to the full mark on the dipstick.

OpErATION

prE-STArT cHEcKLIST (FIG. 3)

Do not operate this

unit until you read and understand

this instruction manual and the engine

instruction manual for safety, operation

and maintenance instructions.

Risk of property damage.

Always check engine oil level before

every start. Running engine low of oil or

out of oil could result in serious damage

to the engine.

Follow the steps listed below before

starting generator:
1. Place unit on level surface.
2. Check engine oil. Refer to

Oil

recommendations

under

Assembly

and

product

Specifications for correct grade

and quantity of oil.

Risk of property damage.

Do not operate engine without oil or

with inadequate oil. PORTER-CABLE

is not responsible for engine failure

caused by inadequate oil.
3. Check fuel level, fill as required.

See

Add Engine Oil and Fuel

under

Assembly.

4. Make sure generator is grounded in

accordance with local requirements.

See

Grounding the Generator

under

Assembly.

5. All electrical loads MUST be

disconnected and main breaker

(AA) in the OFF position.

Risk of explosion or fire.

Engine speed has been factory set to

provide safe operation. Tampering with

the engine speed adjustment could

result in overheating of attachments

and could cause a fire. Never attempt to

“speed-up” the engine to obtain more

performance. Both the output voltage

and frequency will be thrown out of

standard by this practice, endangering

attachments and the user. Tampering

may cause damage to the generator

and voids the warranty.

Risk of property damage.

Unplug any load from the generator

before starting to prevent permanent

damage to any appliances.

STArTING GENErATOr —

(FIG. 1–3, 6–9)

Do not operate this unit

until you read this instruction manual

for safety, operation and maintenance

instructions.
1. Disconnect all electrical loads from

the generator and place the main

breaker (AA) in the OFF position.

2. Turn the fuel

G

6

shut-off valve (G)

on the gas tank

to the vertical

(OPEN) position

as shown.

3. If the engine

is cold, move

the

choke

(Q) to the CLOSED position

shown. If the engine is hot,

move the choke to OPEN

position.

cLOSED

Q

7

cLOSED

Or

Q

4. Turn engine On/Off switch (Z) to

the ON position.