beautypg.com

Shure MX300 User Manual

Page 24

background image

24

1.

All

resistors 1/10W

,

±

1%, 0805, unless otherwise specified.

2.

Electrolytic

capacitors shown

in

µ

F

x

V

olts. All non–polar capacitors

in

µ

F,

±

10%, and 50V or more unless otherwise specified.

3.

= AC V

oltage

= DC V

oltage

= Printed Circuit Ground

= Case Ground

= Logic Ground

= AC V

oltage, Mic Muted (J4 Shorted)

= DC V

oltage, Mic Muted (J4 Shorted)

(+) and/or (–) indicate AC polarity relative to input test signal.

4.

Connect J2 to mic input of a Shure M367 Mixer or

equivalent, with

48V phantom power switched on.

NOTES;

MX392/MX393 SCHEMATIC DIAGRAM

SCHEMA DE PRINCIPE MX392/MX393

STROMLAUFPLAN FUR MX392/MX393

DIAGRAMA ESQUEMATICO DEL MX392/MX393

SCHEMA CIRCUITALE DEI MODELLI MX392/MX393

FIGURE 11

S

FIGURE 11

S

ABBILDUNG 11

S

FIGURA 11

S

FIGURA 11