beautypg.com

ICP DAS USA I-7540D User Manual

Page 33

background image

Note:

If users click the “Defaults” icon, all of the CAN communication

parameters in the i-7540D will be set to the default values, which are:

CAN

Specification

=

2.0B

CAN

bus

Baud

rate

=

1Mbps

BTR0 = 00 BTR1 = 00

Acceptance

Code

=

00

00

00

00

Acceptance Mask = FF FF FF FF

Error Response = No

Timestamp

Response

=

No


7. The “Network Status” frame displayed the IP, Gateway, Mask and MAC

address of the i-7540D. Users can change these network parameters by click
the “Set” button and “Modify IP” button. And the “Reset System” checkbox is
used to reset the system of i-7540D.

Note: After modify the network status of the i-7540D, the setting value will

become effective after resetting the system.


8. The “COM Status” frame showed the parameters of RS-232 and RS485 ports.

User also can modify it by click the “Set” button.


9. The “CAN Bus Pair Connection Status” frame showed the parameters of CAN

pair connection.

Note: After modify the CAN bus pair connection status of the i-7540D, the setting

value will become effective after resetting the system.

i-7540D CAN-Ethernet Gateway User’s Manual (Version 1.4, April/2008)

33