Dimensions

Dimensions

Dimensions

Dimensions (H x W x D)
(with bezel)

3.44x 17.64 x 27.50 in (8.75 x 44.80 x 69.88cm)

Weight

Weight

Weight

Weight
(approximate)

Maximum

Maximum

Maximum

Maximum
(all hard drives, power
supplies and processors
installed)

51.5 lb (19.22 kg)

Minimum

Minimum

Minimum

Minimum
(one hard drive, power
supply and processor
installed)

35.0 lb (13.06 kg)

Input

Input

Input

Input
Requirements

Requirements

Requirements

Requirements
(per power supply)

Rated Line Voltage

Rated Line Voltage

Rated Line Voltage

Rated Line Voltage

100 - 240 VAC

Rated Input Current

Rated Input Current

Rated Input Current

Rated Input Current

9.10 A (at 100 VAC),
4.5 A (at 200 VAC)

Rated Input Frequency

Rated Input Frequency

Rated Input Frequency

Rated Input Frequency

50 to 60 Hz

Rated Input Power

Rated Input Power

Rated Input Power

Rated Input Power

910 W (at 100 VAC),
900 W (at 200 VAC)

BTU Rating

BTU Rating

BTU Rating

BTU Rating

Maximum

Maximum

Maximum

Maximum

3107.82 BTU/hr (at 100 VAC),
3073.67 BTU/hr (at 200 VAC)

Power Specifications

Power Specifications

Power Specifications

Power Specifications

To review typical system power ratings use the Power Calculator which is
available via the online tool located at URL:

http://h30099.www3.hp.com/configurator/calc/
Power%20Calculator%20Catalog.xls

Click on the system of interest. Example: DL180 G5
Follow the instructions of the next screens.

Power Supply Output

Power Supply Output

Power Supply Output

Power Supply Output
(per power supply)

Rated Steady-State Power

Rated Steady-State Power

Rated Steady-State Power

Rated Steady-State Power 750 W (at 100 VAC),

750 W (at 200 VAC)

Maximum Peak Power

Maximum Peak Power

Maximum Peak Power

Maximum Peak Power

750 W (at 100 VAC),
750W (at 200 VAC)

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature

System Inlet Temperature

Operating

Operating

Operating

Operating

50° to 95°F (10° to 35°C) at sea level with an
altitude derating of 1.8°F per every 1000 ft
(1.0°C per every 305 m) above sea level to a
maximum of 10,000 ft (3050 m), no direct
sustained sunlight. Maximum rate of change is
18°F/hr (10°C/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 86°F (30°C).

Non-operating

Non-operating

Non-operating

Non-operating

-22° to 140° F (-30° to 60° C). Maximum rate of
change is 36° F/hr (20° C/hr).

Relative Humidity

Relative Humidity

Relative Humidity

Relative Humidity
(non-condensing)

Operating

Operating

Operating

Operating

10 to 90% relative humidity (Rh), 82.4° F (28° C)
maximum wet bulb temperature, non-
condensing.

Non-operating

Non-operating

Non-operating

Non-operating

5 to 95% relative humidity (Rh), 101.7° F (38.7°
C) maximum wet bulb temperature, non-
condensing.

QuickSpecs

HP ProLiant DL180 Generation 5 (G5)

HP ProLiant DL180 Generation 5 (G5)

HP ProLiant DL180 Generation 5 (G5)

HP ProLiant DL180 Generation 5 (G5)

Technical Specifications

DA - 12903 Worldwide — Version 10 — July 14, 2008