Serial menu command, Once the imager is – Hand Held Products HANDHELD 3800G User Manual
Page 113

11 - 7
Beeper Pitch - Good Read
(Frequency)
Low (1600) (min 400Hz)
BEPFQ11600
*Medium (2550)
BEPFQ12550
High (4200) (max 9000Hz)
BEPFQ14200
Beeper Duration - Good
Read
*Normal Beep
BEPBIP0
Short Beep
BEPBIP1
LED - Good Read
Off
BEPLED0
*On
BEPLED1
Number of Beeps - Good
Read
*1
BEPRPT1
Range 1 - 9
BEPRPT#
Good Read Delay
*No Delay
DLYGRD0
Short Delay (500 ms)
DLYGRD500
Medium Delay (1000 ms)
DLYGRD1000
Long Delay (1500 ms)
DLYGRD1500
User-Specified Good Read
Delay
Range 0 - 30,000 ms
DLYGRD####
#
Trigger Mode
*Manual/Serial Trigger
TRGMOD0
Read Time-Out (0 - 300,000
ms) *300,000
TRGSTO####
Automatic Trigger
TRGMOD1
Presentation Mode
TRGMOD3
Continuous Illumination On
ILLAON1
*Continuous Illumination Off
ILLAON0
Hands Free Time-Out (0-
300,000 seconds) *5000
TRGPTO####
##
Reread Delay
Short (500 ms)
DLYRRD500
*Medium (750 ms)
DLYRRD750
Long (1000 ms)
DLYRRD1000
Extra Long (2000 ms)
DLYRRD3000
User-Specified Reread
Delay
Range 0 - 30,000 ms
DLYRRD####
#
Centering
Centering On
DECWIN1
*Centering Off
DECWIN0
Left of Centering Window *40
DECLFT###
Right of Centering Window *60
DECRGT###
Selection
Setting
* Indicates default
Serial
Command
# Indicates a
numeric entry
Page