Maintaining and Servicing Appliance

Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualifi ed
service technician should perform an appliance checkup at the beginning of each heating season.

Annual inspection by qualifi ed technician recommended.

Check:
• Condition of doors, surrounds and fronts.
• Condition of glass, glass assembly and glass seal.
• Obstructions of combustion and ventilation air.
• Condition of logs.
• Condition of fi rebox.
• Burner ignition and operation.
• Burner air shutter adjustment
• Gas connections and fi ttings.
• Obstructions of termination cap.

Clean:
• Glass
• Air passageways, grilles,
control

compartment

• Burner, burner ports

Risk of:
• Fire
• Delayed ignition or explosion
• Exposure to combustion fumes
• Odors

Handle glass assembly with care.
Note: Clean glass after initial 3-4 hours operation.
Longer operation without cleaning glass may
cause a permanent white fi lm on glass.

CAUTION

When cleaning glass door:

• Avoid striking, scratching or slamming glass.

• Do NOT use abrasive cleaners.

• Use a hard water deposit glass cleaner on white fi lm.

• Do NOT clean glass when hot.

• Turn off appliance after 3-4 hours of operation and

ALLOW TO COOL.

• Remove and clean glass assembly.

• Replace glass assembly and operate appliance for

additional 12 hours.

Refer to maintenance instructions.

Risk of injury or property damage.

Before servicing:

• Turn off gas.

• Turn off electricity to appliance.

• Disable remote control, if one is present.

• Ensure appliance is completely cooled.

After servicing:

• Replace any screen or barrier that was removed.

• Reseal and reinstall any venting removed for servicing.

Inspect external vent cap regularly.

• Ensure no debris blocks cap.

• Combustible materials blocking cap may ignite.

• Restricted air fl ow affects burner operation.

WARNING

WARNING

WARNING