D. junction box installation – Heat & Glo Fireplace CERONA-36 User Manual
Page 33
Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. H • 11/08
33
WHITE
JUNCTION
BOX
STRAIN RELIEF
CONNECTOR
FRONT OF
FIREPLACE
COPPER GROUND
ATTACHED TO
GROUND
SCREW WITH
GROUND WIRE
HEAT SHIELD
BOTTOM PAN
GROUND WIRE
INSIDE BOX
BLACK
14/2WG
Figure 10.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram
D. Junction Box Installation
Figure 10.2 Junction Box Detail
Note: Do NOT wire
110VAC to wall switch.
If the box is being wired from the OUTSIDE of the
appliance:
• Loosen screw on the Romex connector, feed the
necessary length of wire through the connector and
tighten the screw.
• Make all necessary wire connections and reattach the
cover plate to the outer shell.
If the box is being wired from the INSIDE of the
appliance:
• Remove the screw attaching the junction box to the outer
shell, rotate the junction box inward to disengage it from
the outer shell (see Figure 10.2).
• Loosen the screw on the Romex connector, feed the
necessary length of wire through the connector and
tighten the screw.
• Pull the electrical wires from outside the appliance
through this opening into the valve compartment.
• Make all necessary wire connections to the receptacle
and assemble the receptacle and cover to the junction
box.
For units WITHOUT factory installed Rocker Switch
* May be labeled as “W” or “Y”.
BROWN
WHITE
BLACK
YELLOW
or
WHITE
BLACK
TOGETHER
CONNECTED
FACTORY
FAN THERMOSTAT
YELLOW
YELLOW
FLAME ON
3V DC
GREEN
RED
BROWN
BLACK
GROUND
BROWN
ADAPTER WIRES
BLACK
RED
RED
BLACK
FLAME HIGH/LOW
SOLENOID
FLAME
MODULE
IPI
ORANGE
G
W*
R
8
7
6
5
4
3
2
1
BATTERIES
ORANGE
CONNECTION
FAN
PLUG
AC
BLACK
BLACK
G W* R
REAR VIEW
FRONT VIEW
CONNECTION
AUX
GREEN
PIGTAIL
GROUND
RED
RED
GREEN
ORANGE
VALVE
IPI
(MALE/FEMALE)
RED
RED
(FEMALE/MALE)
BLACK
RED
SWITCH AND WIRE
ASSEMBLY
SUPPLIED
WITH WSK-MLT