beautypg.com

Warning – Heat & Glo Fireplace CERONA-36 User Manual

Page 16

background image

Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. H • 11/08

16

H

1

V

1

Figure 5.3

Figure 5.4

D. Vent Diagrams

1. Top Vent - Horizontal Termination

One Elbow

Two Elbows

INSTALLED

HORIZONTALLY

H

1

H

2

V

1

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling fi restops.

• ALWAYS maintain specifi ed clearances around venting and fi restop systems.

• Install wall shield and ceiling fi restops as specifi ed.

Failure to keep insulation or other material away from vent pipe may cause fi re.

WARNING

V

1

Minimum

H

1

Maximum

Cerona-36 ONLY

1/2 ft

152 mm

2 ft

610 mm

1 ft

305 mm

2 ft

610 mm

2 ft

610 mm

5 ft

1.5 m

3 ft

914 mm

8 ft

2.4 m

4 ft

1.2 m

11 ft

3.4 m

5 ft

1.5 m

14 ft

4.3 m

6 ft

1.8 m

17 ft

5.2 m

7 ft

2.1 m

20 ft

6.1 m

8 ft

2.4 m

23 ft

7.0 m

V

1

= 40 ft. (12.2 m) Maximum

H

1

= 23 ft. (7.0 m) Maximum

V

1

+ H

1

= 63 ft. (19.2 m) Maximum

Note: Must have
a minimum verti-
cal vent before
attaching a 90º
elbow to the unit.
See chart.

Minimal Vertical Vent

Model

ft.

mm

Cerona-36

1/2

152

Cerona-42

1

305

V

1

Minimum

H

1

Maximum

Cerona-36 ONLY

1/2 ft

152 mm

2 ft

610 mm

1 ft

305 mm

2 ft

610 mm

2 ft

610 mm

5 ft

1.5 m

3 ft

914 mm

8 ft

2.4 m

4 ft

1.2 m

11 ft

3.4 m

5 ft

1.5 m

14 ft

4.3 m

6 ft

1.8 m

17 ft

5.2 m

7 ft

2.1 m

20 ft

6.1 m

8 ft

2.4 m

23 ft

7.0 m

V

1

+ H

1

+ H

2

= 63 ft. (19.2 m) Maximum

H

1

+ H

2

= 23 ft. (7.0 m) Maximum

Note: Must have
a minimum verti-
cal vent before
attaching a 90º
elbow to the unit.
See chart.

Minimal Vertical Vent

Model

ft.

mm

Cerona-36

1/2

152

Cerona-42

1

305

This manual is related to the following products: