D. installing flue restrictors – Heat & Glo Fireplace CERONA-36 User Manual
Page 23

Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev. H • 11/08
23
D. Installing Flue Restrictors
Locate the fl ue restrictor and two screws inside the manual
bag. Use the following table to determine which restrictors
to use for the vent run.
Vent Run Vertical
15 ft. - 50 ft.
Cerona-36
1-1/4
Cerona-42
1-1/4
Figure 7.5
• Attach the left and right side pieces to the framing
members. (See Figure 7.3).
• Use a wet or dry towel or soft brush to remove dust or
dirt from facing material.
• Apply a non-combustible adhesive to attach tile,
stone or other non-combustible fi nishing materials per
manufacturer’s instructions.
Figure 7.4 Complete Installation of Non-combustible
Facing
Material
A
B
Cerona-36
in.
43-5/8
50-3/16
mm
1108
1275
Cerona-42
in.
50-5/8
54-3/8
mm
1286
1381
A
B
NON-COMBUSTIBLE
FACING MATERIAL
1 in.
(25 mm)
BOTTOM
OF FIREPLACE
TOP OF
FIREPLACE
EXHAUST
COLLAR
EXHAUST
PORT
SCREWS
FIREBOX
FLUE
RESTRICTOR
FLUE
RESTRICTOR
FLAPPER
DOOR
FLAPPER
DOOR
EXHAUST
COLLAR
EXHAUST
PORT
SCREWS (2)
Mount the fl ue restrictor to the fl apper door using two
screws (see Figure 7.5).