26

26

OPERATION

Permanent Manual Override

To hold your Manual Override for vacation or just an extended period of time:

■ Press to make the current program temperature the

HOLD temperature. HOLD will be displayed on the
LCD, and the Program number will disappear.

■ Follow the Temporary Manual Override instructions

above to change the Permanent Manual Override
temperature.

■ You can confirm the held set temperature by press-

ing for less than 1 second.

To end the Permanent Manual Override:

■ Press again. The thermostat will return to the current

program, and the HOLD display will be canceled.

hold

/return

TEMP

PM

TH

HOLD

hold

/return

41659_model47350A_web.pmd

27

Vacation Override (Programmable Hold)

This thermostat can hold a fixed temperature for a selected number of days (up to 30). After the selected number
of days, the thermostat will return to normal program operation. This feature allows you to return home to your
normal comfort setpoint temperatures.

■ Press and hold for 2 seconds. Display will change to

show a 1 day hold.

■ Press to select the number of days to set the

vacation hold temperature. In this example,
14 is used.

■ Press to set the desired temperature.

■ Press to return to normal mode, or wait 5 seconds

for it to return automatically.

■ HOLD will be shown on the LCD, and “VACA” will

alternate with the time.

day/time

hold

/return

TEMP

COOL

SET TEMP

HOLD

TEMP

COOL

SET TEMP

HOLD

or

hold

/return

TEMP

HOLD