beautypg.com

Hunter Fan 44665 User Manual

Ch rhtemp c, Ch temp, Setup initial start-up

background image

Ch

TEMP

Form No. 44004-01 R030409

Your Model 44668/44665 thermostat

can read the temperature from up to

three weather-resistant sensors at a

distance of up to 75 feet.
Note: Distance my vary based on

building construction or other interfering

frequencies.
You can control the temperature from

one indoor sensor and/or thermostat,

with the second and third being a sensor

only. If you use multiple sensors, you

might want to number them. Simply use

a marker to write a number on the back

of each sensor. The remote sensors are

designed to either be mounted on a wall,

or set on a desk or side table.
Consult the Thermostat Instruction

Manual for instructions in setting the

thermostat to accommodate the remote

sensors.
You may also download directly from

Hunter Fan Company at www.hunterfan.

com/support.

1. Remove the four screws on the back

of the Remote Sensor. See Figure 1. The

Outer Cover will drop off.

2. Remove the Battery Compartment

Cover, which is underneath the Outer

Cover. See Figure 2.

Figure 1.

Outer Cover

4. Install two fresh AA alkaline batteries

into the Battery Compartment, being

careful to observe the battery polarities.

See Figure 4.

Figure 2.

Battery
Cover

3. Use the tip of a paper clip to set

the FIRST FOUR Remote Sensor DIP

Switches to any configuration you desire.

NOTE: Each sensor you use must have a

different setting. See Figure 3.

To set the remote sensor to display the

temperature in Fahrenheit, place the

FIFTH DIP switch in the DOWN position.

To set the remote sensor to display the

temperature in Celsius, place the FIFTH

DIP switch in the UP position.

Battery

Compartment

(Batteries

installed)

Figure 4.

1. When the batteries are installed, the

LCD Display will show the first initializing

screen for approx. 2 seconds. See Figure

5.

2. The LCD Display will then show the

second initializing screen for approx. 10

seconds. See Figure 6.

Ch RHTEMP

C

%

Figure 5.

Ch

Figure 6.

Figure 3.

ON

DIP

1 2 3 4 5

Model 44758 Remote Sensor

Owners Manual

Setup

InItIal Start-up

3. The LCD Display will then show the

normal operating screen. See Figure 7.

NOTE: It may take up to 30 seconds for

the thermostat to "pick-up" the sensor.

Ch

TEMP

Figure 7.

Channel

4. The Remote Sensor Screen will

display the ambient temperature and, in

the bottom-left corner, a channel number

between 0 and 15. See Figure 7. This

will be the channel to which you will set

the thermostat to read the Remote Sensor.

See the Thermostat Instruction Manual,

page 14, Option 8.
5) Place the Battery Compartment Cover

over the Battery Compartment.

Wall MountIng

1. Replace the Outer Cover as shown in

Figure 8. Use the four screws to secure

the Outer Cover.