Controller ip address, Controller port number – Home Automation OmniPro II User Manual

Page 86

background image

DST

START

WEEKEND:

FIRST SUNDAY #=CHNG


DST END MONTH: 10

1-12 0=DISABLE


DST END WEEKEND:

LAST SUNDAY #=CHNG


Set the value for DST Start and End Months to "0" if Daylight Savings Time does not apply to your region, or to disable this
automatic time update feature.

The DST Start and End Weekend takes place on the specified Sunday (1-7) at 2:00 AM.

To change the DST Start or End Weekend, press the ' # ' key, then use the arrow keys to scroll through the list. Press the ' # ' key
to make the new selection

.


NUMBER DESCRIPTION

1

First

Sunday

2

Second

Sunday

3

Third

Sunday

4

Fourth

Sunday

5

Last

Sunday

6

Next

to

Last

Sunday

7

Third

from

Last

Sunday


Controller IP Address

The controller’s local network IP address is used to identify the OmniPro II controller on the network. To view and assign the
controller’s local network IP address, from the Set Up menu, press the 6 (MISC) key. Using the down arrow key (

), scroll to the

following menu item:

IP

ADDRESS

192.168.0.101


The format of the IP address is a 32-bit numeric address written as four numbers separated by periods. An IP address has two
components, the network address, and the host address. The first two numbers (e.g. 192.168) represent the Class B network
address and must be the same as the first two numbers of your local network. The second two numbers (e.g. 0.101) identify a
particular host on the local network and may be assigned at random as long as each device on the local network has a unique
address. Each number can be 0 to 255. Enter the 1, 2, or 3 digit number followed by the “#” key to move to the next number.
After the 4

th

number has been entered, press the “#” key to store the IP address.


Controller Port Number

The controller’s local network port number identifies the logical channel to the OmniPro II controller. For example, port 80 is
used for HTTP traffic; the controller’s local network port number is used for Omni-Link traffic. To view and assign the
controller’s local network port number, from the previous Setup item (IP ADDRESS), press the down arrow key (

).


PORT NUMBER 4369

0-65535

In most installations, the default port number can remain the same. Port numbers range from 0 to 65535. To change the port
number, enter the new port number followed by the “#” key to store the port number. Port numbers 0 to 1024 are reserved for
designated services and should not be used.

Page 78