Enable Freeze Alarm
If there are one or more Thermostat or PESM in a system, they can also be used to detect a freeze condition - See Freeze Alarm.
The default for Enabled Freeze Alarm is No.
Flash For Alarm
You may enter one unit number that will flash on and off continuously when the alarm is activated. This should be an outside
light to alert neighbors and police to your property if the alarm is activated.
The default Flash For Alarm is Unit 2. You may enter one number for the unit number you wish to have flash, or ' 0 ' for none.
House Codes 1-16 Format
House Codes 1-16 can be configured to use the Standard (Preset Dim Command), Extended Code (Level Command), Lightolier's
Compose Mode, UPB (open transmission format), Lutron’s RadioRA transmission format, HAI Lighting (HLC), and CentraLite
transmission format.
HC 1 FORMAT: 5
HAI LIGHTING #=CHNG
To change format for House Code 1, press the ' # ' key, and then use the arrow keys to scroll through the list of formats. Press the
' # ' key to select the desired format
.
After selecting, press the down-arrow key to change format for the next House Code.
FORMAT NUMBER
DESCRIPTION
STANDARD
0
Preset Dim Command (X-10, X-10 Pro, Leviton, PCS, etc.)
EXTENDED
1
Extended Code Level Command (Leviton)
COMPOSE
2
Compose
Mode
(Lightolier's
Compose)
UPB
3
Universal
Powerline
Bus
(open
format)
RADIO
RA
4
Lutron
RadioRA
HAI
LIGHTING
5
HAI
Lighting
Control
(HLC)
CENTRALITE
6
CentraLite
Lighting
The default setting for HC 1-16 Format is 5 (HLC).
House Codes 1-16 All Off
This feature allows you to choose if House Code 1-16 will respond to the “All Off” command. Press the 0 key to select No and
the 1 key to select Yes. After selecting, press the down-arrow key to change this option for the next House Code.
HC 1 ALL OFF: 1
0=NO 1=YES
The default setting for HC 1-4 All Off is Yes.
Notes:
1. When configured, each House Code will affect 2 rooms of HLC lighting (i.e. HC 1 ALL OFF affects Room 1 and 2).
2. When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All Off” does not affect the state of the
installed devices; however, if this setup item is set to “Yes”, OmniPro II will change the status of all units on that House
Code to “Off” (even though it doesn’t explicitly send an All Off command to those units). If the “House Code All Off” setup
item is set to “No”, OmniPro II will not change the status of units on that House Code.