Chapter 3 – parameter setting tables – Hitachi SJ300 Series User Manual
Page 31

31
Chapter 3 – Parameter Setting Tables
*P090
Frequency 1 for I-gain
adjustment
0.-max.frequency 0.3
*P091
Frequency 2 for I-gain
adjustment
0. or P090-max.frequency
0.7
*P092
Frequency 3 for I-gain
adjustment
0. or P091-max.frequency
1.0
*P093
Frequency 4 for I-gain
adjustment
0. or P092-max.frequency
2.0
*P094
Frequency 5 for I-gain
adjustment
0. or P093-max.frequency
50.0
*P095
Frequency 6 for I-gain
adjustment
0. or P094-max.frequency
50.0
*P096
Frequency 7 for I-gain
adjustment
0. or P095-max.frequency
50.0
*P097
Frequency 8 for I-gain
adjustment
0. or P096-max.frequency
50.0
P100 I-gain
1
0.-100.(%)
80.
P101 I-gain
2
0.-100.(%)
70.
P102 I-gain
3
0.-100.(%)
60.
P103 I-gain
4
0.-100.(%)
50.
P104 I-gain
5
0.-100.(%)
50.
P105 I-gain
6
0.-100.(%)
50.
P106 I-gain
7
0.-100.(%)
50.
P107 I-gain
8
0.-100.(%)
50.
P110
FW side balance value
0.0-10.0(v)
0.0
P111
RV side balance value
0.0-10.0(v)
0.0
P112 FW
side
gain
0.0-200.0(%)
0.0
P113
RV side gain
0.0-200.0(%)
0.0
P114
Time constant of the filter
5.-500.(ms)
5.
Option
*X00x
Note: Parameters indicated with an asterisk and yellow highlight are affected by
setting of the frequency conversion function (parameter A074). See the function
description in Chapter 2. In addition to the parameters listed above, the following
parameters will also be scaled if this function is enabled:
D007 – Scaled Output Frequency Monitor
F001 – Output Frequency Setting