Chapter 3 – Parameter Setting Tables

Function mode

Code

Function name

Setting range

Initial data

remarks

C001

Intelligent input 1 setting

18(RS)

C002

Intelligent input 2 setting

15(SFT)

C003

Intelligent input 3 setting

09(2CH)

C004

Intelligent input 4 setting

11(FRS)

C005

Intelligent input 5 setting

04(CF3)

C006

Intelligent input 6 setting

03(CF2)

C007

Intelligent input 7 setting

02(CF1)

C008

Intelligent input 8 setting

01/(RV:Reverse is valid)/02(CF1:Multi-speed1)/ 03(CF2:Multi-speed2)/
04(CF3:Multi-speed3)/07(DB:External DC braking)/
09(2CH:two-stage adjustable speed)/ 11(FRS:Free-run)/
12(EXT:External trip)/13(USP:Unattended start protection)/
14(CS:commercial change)/15(SFT:software lock)/
16(AT:Analog input voltage/current select)/18(RS:Reset inverter)/
20(STA:3wire run)/ 21(STP:3wire keep)/ 22(F/R:3wire forward/reverse)/
26(CAS:Control gain switch function)/
31(OPE:Operating by operator select)/ 32(SF1:Multi-speed bit1)/
33(SF2:Multi-speed bit2)/ 34(SF3:Multi-speed bit3)/
35(SF4:Multi-speed bit4)/36(SF5:Multi speed bit5)/
37(SF6:Multi-speed bit6)/ 38(SF7:Multi-speed bit7)/
39(OLR:Overload restriction change) / 40(TL:Torque limit select)/
41(TRQ1:Torque limit switch 1)/42(TRQ2:Torque limit switch 2)/
43((PPI:P/PI switch)/44(BOK:Braking comformation)/
45(ORT:Orientation)/ 46(LAC:LAD cancel)/
47(PCLR:Position error clear)/ 48(STAT: Permission of pulse train)/
50(SSD:Torque bias hold)/52(ECM:Changeover in case of emergency)/
no (NO: No assign)

01(RV)

C011

Intelligent input 1 a/b (NO/NC)
selection

00(NO)/01(NC) 00

C012

Intelligent input 2 a/b (NO/NC)
selection

00(NO)/01(NC) 00

C013

Intelligent input 3 a/b (NO/NC)
selection

00(NO)/01(NC) 00

C014

Intelligent input 4 a/b (NO/NC)
selection

00(NO)/01(NC) 00

C015

Intelligent input 5 a/b (NO/NC)
selection

00(NO)/01(NC) 00

C016

Intelligent input 6 a/b
(NO/NC) selection

00(NO)/01(NC) 00

C017

Intelligent input 7a/b
(NO/NC) selection

00(NO)/01(NC) 00

C018

Intelligent input 8 a/b
(NO/NC) selection

00(NO)/01(NC) 00

C019

Input FW a/b (NO/NC)
Selection

00(NO)/01(NC) 00

C021

Intelligent output 11 setting

01(FA1)

C022

Intelligent output 12 setting

00(RUN)

C023

Intelligent output 13 setting

03(OL)

C024

Intelligent output 14 setting

19(BRK)

C025

Intelligent output 15 setting

21(ZS)

C026

Alarm relay output

00(RUN: running) / 01(FA1:Frequency arrival type1 signal) /
02(FA2:over setting frequency) / 03(OL: Overload advance notice signal)/
05(AL: Alarm signal)/06(FA3:Only setting frequency) /
07(OTQ: Over-torque signal) / 08(IP: On instantaneous stop) /
09(UV: Under voltage) / 10(TRQ: Torque limit)/
11(RNT: RUN time over) / 12(ONT:ON time over) / 13(THM: thermal caution) /
19(BRK: Brake release signal) / 20(BER: Brake error signal) /
21(ZS: Zero speed detect signal)/22(DSE: Speed error over signal) /
23(POK: Positioning completion signal)/24(FA4:Over frequency 2 signal)/
25(FA5: Only setting frequency) /
26(OL2: Overload advance notice signal (2)
(Intelligent output terminal 11-13 or 11-14 becomes AC0-AC2 or AC0-AC3
(Can: Alarm code output) forcibly when alarm code output is selected in C062)

05(AL)

C027 FM

selection

00(Output frequency)/01(Output current) /02(Output torque)/
03(Digital output frequency)/04(Output voltage)/
05(Input electric power)/06(thermal load rate)/07(LAD frequency)

00

C028 AM

selection

00(Output frequency)/01(Output current)/02(Output torque)/
04(Output voltage)/05(Input electric power)/06(thermal load rate)/
07(LAD frequency)

00

C029 AMI

selection

00(Output frequency)/01(Output current)/02(Output torque)/
04(Output voltage)/05(Input electric power)/
06(Thermal load rate)/07(LAD frequency)

00

C031

Intelligent output 11 a/b

00(NO)/01(NC)

00

C032

Intelligent output 12 a/b

00(NO)/01(NC)

00

C033

Intelligent output 13 a/b

00(NO)/01(NC)

00

C034

Intelligent output 14 a/b

00(NO)/01(NC)

00

C035

Intelligent output 15 a/b

00(NO)/01(NC)

00

C036

Alarm relay output a/b

00(NO)/01(NC)

01

In

te

llig

en

t inp

u

t te

rmina

l se

tting

In

te

llig

en

t I

n

pu

t t

e

rmin

a

l a

c

tive

st

at

e set

ti

ng

In

te

llig

en

t o

u

tp

u

t te

rmin

a

l

se

tt

in

g

Analo

g

Ou

tpu

ts

O

u

tput t

e

rm

in

a

l s

tate s

e

tti

n

g

O

u

tput lev

e

l

s

e

tt

ing