Chapter 3 – Parameter Setting Tables
Function Mode
Code
Function name
Setting range
Initial data
remarks
A092 Acceleration
time2
0.01-99.99/100.0-999.9/1000.-3600.(s)
15.00
A093 Deceleration
time2
0.01-99.99/100.0-999.9/1000.-3600.(s)
15.00
A094 2
nd
stage adjustable selection
00(change with 2CH terminal)/01(change with setting)
00
*A095 2
nd
acceleration frequency
0.00-99.99/100.0-400.0(Hz)
0.00
*A096 2
nd
deceleration frequency
0.00-99.99/100.0-400.0(Hz)
0.00
A097 Acceleration
pattern
selection
00(straight line)/01(S-curve)/02(U-curve)/03(reverse U-curve)/
04(EL-S curve)
04
A098 Deceleration
pattern
selection
00(straight line)/01(S-curve)/02(U-curve)/03(reverse U-curve)/
04(EL-S curve)
04
*A101 OI
start
frequency
0.00-99.99/100.0-400.0(Hz)
0.00
*A102 OI
end
frequency
0.00-99.99/100.0-400.0(Hz)
0.00
A103
OI start current
0.-100. (%)
20.
A104
OI end current
0.-100. (%)
100.
A105
OI start selection
00(external start frequency)/01(0Hz)
01
*A111 O2
start
frequency
0.00-99.99/100.0-400.0(Hz)
0.00
*A112 O2
end
frequency
0.00-99.99/100.0-400.0(Hz)
0.00
A113
O2 start voltage
0.-100. (%)
-100%
A114
O2 end voltage
0.-100. (%)
100%
A131
Acceleration curve constant
01(small swelling)-10(large swelling)
01
A132
Deceleration curve constant
01(small swelling-10(large swelling)
01
b001 Retry
selection
00(trip)/01(0Hz start)/02(start after equal frequency)/
03(trip after equaling frequency and deceleration stop)
00
b002
Allowable under-voltage power
failure time
0.3-1.0(s) 0.3
b003 Retry
wait
time
0.3-100.(s)
1.0
b004
Instantaneous power failure/
under-voltage trip during stop
00(invalid/01(valid)/02(invalid during stop and deceleration by stop
command)
01
b005
Instantaneous power failure/
under-voltage retry time
selection
00(16 times)/01(free)
00
b006 Open-phase
selection
00(invalid)/01(valid)
00
*b007
Frequency setting to match
0.00-99.99/100.0-400.0(Hz)
0.00
b012
Electronic thermal level
0.2*constant current-1.20*constant current (A)
Rated
Current of
inverter
b013
1
st
electronic thermal
characteristic selection
00(reduced characteristic)/ 01(constant torque characteristic)/
02(free setting)
01
*b015
Free electronic thermal frequency
1
0.-400.(Hz) 0.
b016
Free electronic thermal current
1
0.0-1000.(A) 0.0
*b017
Free electronic thermal frequency
2
0.-400.(Hz) 0.
b018
Free electronic thermal current
2
0.0-1000. (A)
0.0
*b019
Free electronic thermal frequency
3
0.-400.(Hz) 0.
b020
Free electronic thermal current
3
0.0-1000.(A) 0.0
b021
Overload restriction selection
00(invalid)/01(enabled on acceleration / constant speed)/
02(enabled on constant speed)/03(enabled on acceleration / constant speed
(speed increasing at regenerating mode))
01
b022
Overload restriction level
0.50* rated current-2.00* rated current(A)
Rated
current
of
Inverter
x 1.50
b023
Overload restriction limit constant
0.10-30.00(s)
1.00
b024
Overload restriction 2 selection
00(invalid)/01(enabled on acceleration / constant speed)/
02(enabled on constant speed)/03(enabled on acceleration / constant speed
(speed increasing at regenerating mode))
01
b025
Overload restriction level 2
0.50*rated current-2.00*rated current(A)
Rated
current
of
Inverter
x 1.50
b026
Overload restriction constant 2
0.10-30.00(s)
1.00
b031
Software lock mode selection
00(impossible to change the data except this item when SFT terminal is
ON)/01(impossible to change the data except setting frequency item when SFT
terminal is ON)/02(impossible to change the data except this item)/
03(impossible to change the data except setting frequency item)/
10(possible to change data on operating)
01
adj
us
tabl
e fu
ncti
o
n
Ex
terna
l freq
uenc
y
adj
us
tmen
t
Accel.
De
ce
l.
In
s
tantane
ous
powe
r f
a
ilur
e
r
e
s
tar
t
El
ectr
oni
c
t
h
er
m
a
l
Over
load l
im
it
Lock