Chapter 3 – Parameter Setting Tables
Function mode
Code
Function name
Setting range
Initial data
remarks
C040
Overload advance notice
signal output mode
00(On accel. And decel, constant speed)/01(Only constant speed)
01
C041
Overload advance notice level
0.0-2.0*rated current(A)
Inverter
rated current
*C042
Frequency arrival setting for
acceleration.
0.00-99.99/100.0-400.0(Hz) 0.00
*C043
Arrival frequency setting for
deceleration.
0.00-99.99/100.0-400.0(Hz) 0.00
*C045
Frequency arrival setting for
acceleration 2.
0.00-99.99/100.0-400.0(Hz) 0.00
*C046
Arrival frequency setting for
deceleration 2.
0.00-99.99/100.0-400.0(Hz) 0.00
C055
Over torque level setting
(Forward-driving)
0.-200.(%)
100.
C056
Over torque level setting
(Reverse-regenerating)
0.-200.(%) 100.
C057
Over torque level setting
(Reverse-driving)
0.-200.(%) 100.
C058
Over torque level setting
(Forward-regenerating)
0.-200.(%) 100.
C061
Thermal warning level
setting
0.-100.(%) 80.
C062
Alarm code selection
00(Invalid)/01(3bit)/02(4bit)
00
*C063
Zero speed detection level
setting
0.00-99.99/100.(Hz) 0.00
C070 Data
command
02(operator)/03(RS485)/04(option1)/05(option2)
02
C071
Communicating transmission
speed
02(loop-back test)
03(2400bps)/04(4800bps)/05(9600bps)/06(19200bps)
04
C072
Communication code
1. -32.
1.
C073 Communication
bit
7(7bit)/8(8bit)
7
C074
Communication parity
00(no parity name)/01(even parity)/02(odd parity)
00
C075
Communication stop bit
1(bit)/2(bit)
1
C078
Communication waiting time
0.-1000.(ms)
0.
C081 O
adjustment
0.-9999./1000-6553(10000-65530)
Setting on
forwarding
C082 OI
adjustment
0.-9999./1000-6553(10000-65530)
Setting on
forwarding
C083 O2
adjustment
0.-9999./1000-6553(10000-65530)
Setting on
forwarding
C085
Thermistor adjustment
0.0 - 1000.
105.0
C086
AM offset adjustment
0.0 - 10.0(V)
0.0
C087
AMI adjustment
0. - 255.
80
C088
AMI offset adjustment
0. - 20.0(mA)
Setting on
forwarding
b034
RUN time/Power ON time level
0.-9999./1000-6553(10000-65530)hr
0.
b036
Start reduced voltage
00(Start reduced voltage time small)-06(Start reduced voltage time large)
06
b037
Display selection
00(all display)/01(each function display)/02(User setting / main setting)
00
b040
Torque limit mode selection
00(4 quadrant mode)/01(Terminal operation)/
02(Analog input)/03(Option1)/04(Option2)
00
b041
Torque limit level 1 setting
(Forward-driving at
4 quadrant mode)
0.-200.(%)/no(Invalid) 150.
b042
Torque limit level 2 setting
(Reverse-regenerating at
4 quadrant mode)
0.-200.(%)/no(Invalid) 150.
b043
Torque limit level 3 setting
(Reverse-driving at
4 quadrant mode)
0.-200.(%)/no(Invalid) 150.
b044
Torque limit level 4 setting
(Forward-regenerating at
4 quadrant mode)
0.-200.(%)/no(Invalid) 150.
b045 Torque
LAD-STOP
selection
00(Invalid)/01(Valid)
00
b046
Reverse run prevention
selection
00(Invalid)/01(Valid) 00
b080
AM adjustment
0. - 255.
180
b081
FM adjustment
0. - 255.
60
*b082 Start
frequency
adjustment
0.10-9.99(Hz)
0.10
b083
Carrier frequency setting
0.5-15.0(kHz) Derating enable, <0.5-10kHz>
5.0
b084
Initialize mode
00(Trip history clear)/01(Data initialization)/
02(Trip history clear + data initialization)
00
b086
Frequency scalar conversion
factor
0.1-99.9
1.0
b087
STOP key enable
00(valid)/01(invalid)
00
O
u
tput t
e
rm
inal s
tat
e s
e
tt
ing •
O
u
tput lev
e
l
s
e
tt
ing
C
o
m
m
u
ni
cati
on
functio
n
a
d
justm
e
n
t
A
n
a
log
me
te
r se
tt
ing
Miscel
laneou
s