System Inlet
Temperature

Operating

10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).

Non-operating

-30° to 60°C (-22° to 140°F). Maximum rate
of change is 20°C/hr (36°F/hr).

Relative Humidity
(non-condensing)

Operating

10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature,
non-condensing.

Non-operating

5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.

Altitude

Operating

3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).

Non-operating

9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).

Acoustic Noise

Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
74) and declared in accordance with ISO 9296 (ECMA 109).

Idle

LWAd

6.82 B

LpAm

51.93 dBA

Operating

LWAd

6.84 B

LpAm

51.93 dBA