Hitachi SJ700-2 Series User Manual
Page 19

1 - 15
Default
Code
Function name
Monitored data or setting
_FF _FEF
_FUF
Note
H050
PI proportional gain for 1st motor
0.0 to 999.9, 1000.
100.0
H250
PI proportional gain for 2nd motor
0.0 to 999.9, 1000.
100.0
H051
PI integral gain for 1st motor
0.0 to 999.9, 1000.
100.0
H251
PI integral gain for 2nd motor
0.0 to 999.9, 1000.
100.0
H052
P proportional gain setting for 1st
motor
0.01 to 10.00
1.00
H252
P proportional gain setting for 2nd
motor
0.01 to 10.00
1.00
H060
Zero LV lmit for 1st motor
0.0 to 100.0
100.0
H260
Zero LV lmit for 2nd motor
0.0 to 100.0
100.0
H061
Zero LV starting boost current for
1st motor
0. to 50. (%)
50.
H261
Zero LV starting boost current for
2nd motor
0. to 50. (%)
50.
H070
Terminal selection PI proportional
gain setting
0.0 to 999.9, 1000.
100.0
H071
Terminal selection PI integral gain
setting
0.0 to 999.9, 1000.
100.0
H072
Terminal selection P proportional
gain setting
0.00 to 10.00
1.00
Cont
ro
l cons
tan
ts
H073
Gain switching time
0. to 9999. (ms)
100.