Hitachi SJ700-2 Series User Manual
Page 17

1 - 13
Default
Code
Function name
Monitored data or setting
_FF _FEF
_FUF
Note
Te
rm
inal
C111
Overload setting (2)
0.0 to 2.00 x "rated current" (A)
Rated current of
inverter
C121
[O] input zero calibration
0. to 9999., 1000 to 6553 (10000 to 65530)
Factory setting
C122
[OI] input zero calibration
0. to 9999., 1000 to 6553 (10000 to 65530)
Factory setting
Adjust
m
ent
C123
[O2] input zero calibration
0. to 9999., 1000 to 6553 (10000 to 65530)
Factory setting
C130
Output 11 on-delay time
0.0 to 100.0 (s)
0.0
C131
Output 11 off-delay time
0.0 to 100.0 (s)
0.0
C132
Output 12 on-delay time
0.0 to 100.0 (s)
0.0
C133
Output 12 off-delay time
0.0 to 100.0 (s)
0.0
C134
Output 13 on-delay time
0.0 to 100.0 (s)
0.0
C135
Output 13 off-delay time
0.0 to 100.0 (s)
0.0
C136
Output 14 on-delay time
0.0 to 100.0 (s)
0.0
C137
Output 14 off-delay time
0.0 to 100.0 (s)
0.0
C138
Output 15 on-delay time
0.0 to 100.0 (s)
0.0
C139
Output 15 off-delay time
0.0 to 100.0 (s)
0.0
C140
Output RY on-delay time
0.0 to 100.0 (s)
0.0
C141
Output RY off-delay time
0.0 to 100.0 (s)
0.0
C142
Logical output signal 1 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C143
Logical output signal 1 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C144
Logical output signal 1 operator
selection
00 (AND), 01 (OR), 02 (XOR)
00
C145
Logical output signal 2 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C146
Logical output signal 2 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C147
Logical output signal 2 operator
selection
00 (AND), 01 (OR), 02 (XOR)
00
C148
Logical output signal 3 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C149
Logical output signal 3 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C150
Logical output signal 3 operator
selection
00 (AND), 01 (OR), 02 (XOR)
00
C151
Logical output signal 4 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C152
Logical output signal 4 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C153
Logical output signal 4 operator
selection
00 (AND), 01 (OR), 02 (XOR)
00
C154
Logical output signal 5 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C155
Logical output signal 5 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C156
Logical output signal 5 operator
selection
00 (AND), 01 (OR), 02 (XOR)
00
C157
Logical output signal 6 selection 1 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
C158
Logical output signal 6 selection 2 Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00
O
ut
pu
t t
er
m
inal oper
at
io
n f
unc
tion
C159
Logical output signal 6 operator
selection
00 (AND), 01 (OR), 02 (XOR)
00
C160
Input terminal response time
setting 1
0. to 200. ( ¯2ms) 1
C161
Input terminal response time
setting 2
0. to 200. ( ¯2ms) 1
C162
Input terminal response time
setting 3
0. to 200. ( ¯2ms) 1
C163
Input terminal response time
setting 4
0. to 200. ( ¯2ms) 1
C164
Input terminal response time
setting 5
0. to 200. ( ¯2ms) 1
C165
Input terminal response time
setting 6
0. to 200. ( ¯2ms) 1
C166
Input terminal response time
setting 7
0. to 200. ( ¯2ms) 1
C167
Input terminal response time
setting 8
0. to 200. ( ¯2ms) 1
Input t
er
m
inal
re
sponse
C168
Input terminal response time
setting FW
0. to 200. ( ¯2ms) 1
Oth
er
C169
Multistage speed/position
determination time
0. to 200. ( ¯10ms) 0