beautypg.com

Agitator brush roll replacement, Edge groomer replacement, Headlight replacement – Hoover S3670 User Manual

Page 10

background image

3-18

3-19

Agitator brush roll

replacement

When to replace

Disconnect cleaner from electrical

outlet.

When agitator brush roll brushes are worn, the

brush roll should be replaced.
To check condition of brushes, move edge of

a card across bottom plate while turning brush

roll. To maintain cleaning effectiveness,

replace brush roll if brushes do not touch

card.

What to buy

When purchasing a new agitator brush roll,

ask for HOOVER part no. 48414071.

How to replace

Disconnect cleaner from electrical

outlet.
1. Remove hood, duct cover, belt and brush

roll as shown in Figs. 3-9 to 3-14.

2. Discard old brush roll.
3. Replace new brush roll and belt as shown

in Figs. 3-15 to 3-17.

2. Push old bulb into socket and twist to

remove. Push new bulb into socket and twist

into place.
3. Replace hood.

3-20

Edge groomer

replacement

When to replace

The edge groomers, located on both sides of

the nozzle, should be replaced when they no

longer extend past the surface of the bottom

plate.

What to buy

When purchasing edge groomers, ask for

Hoover part no. 39511004.

How to replace

Disconnect cleaner from electrical

outlet.
1.

Remove hood and brush roll cover as

shown in Figs. 3-9 to 3-12.

Headlight

replacement

The headlight, located on top of the power

nozzle, operates when the cleaner is turned

on. Use only HOOVER part no.

27317307, which is a fused bulb, when

replacing the headlight.

How to replace

Disconnect cleaner from electrical

outlet and disconnect power nozzle

from extension wands.
1. Remove the hood as shown in Figs. 3-9

and 3-10.

H

G

10

2. Pull off both old edge groomers (G).
3.Push each new groomer onto the 3 tabs

(H), starting with one of the end tabs. Then

push the groomer onto the middle and

remaining end tab.
4. Replace brush roll cover and hood as

shown in Figs. 3-16 and 3-17.