(4) Roof

Radiation

Shields

Chimney Section

Chimney Section

Attic Insulation

Shield & Collar

Square Frame

Firestop

Square Frame

Firestop

Chimney Section

74 1/8 in.

(1883 mm)

Effective

Height

Termination

Cap

Storm

Collar

Chase Top

Flashing

Figure 8.1

Determine the chimney components needed to complete

your particular installation:
• Measure the total vertical height of the fireplace installation

from the base of the fireplace assembly to the approximate

location of the bottom of the termination cap.

• Subtract the effective height of the fireplace assembly (see

Figure 8.1) from the total vertical height to determine the

overall height of the chimney installation.

• Create a schematic for your application similar to Figure

8.1 showing components required (referring to Table

8.1).

• Install a ceiling firestop whenever the chimney penetrates

a floor/ceiling.

NOTICE: A maximum of two offset and return may be

used.

CAUTION! Risk of Fire and/or Asphyxiation! DO NOT

connect this fireplace to a chimney flue servicing another

appliance. Do NOT connect to any air distribution duct

or system. These actions could cause overheating/fire

in the chimney flue, or release of exhaust fumes into the

living areas.

Heatilator • Birmingham BIR50-B • 4059-682D • 9/12