5-2. ERROR CODES
(Continued)
DISPLAY
CAUSE
PANEL BOARD CORRECTION
“E-20 A” Vacuum
Press the timer button to try the ignition process again;
switch failure
if “E-20 A” persists check vacuum switch; refer to
(stuck closed)
Technical Manual
“E-20 B”
Draft fan or
Press the timer button to try the ignition process again;
vacuum
if “E-20 B” persists, check vacuum switch or the blower
switch failure
motor; refer to Technical Manual
(stuck open)
“E-20 C” Ignition modules
Press the timer button to try the ignition process again; if
not responding “E-20 C” persists, check the ignition
module, the spark ignitor, or the I/O board; refer to
Technical
Manual
“E-20 D”
Pilots not lit or
Press the timer button to try the ignition process again; if
no flame sense
“E-20 D” persists, check the ignition module, the I/O
board, or the flame sensor; refer to Technical Manual
“E-31”
Elements up-
Lower elements into frypot
Electric
units
only
Fan switch jumper
Check for jumper wire on 12-pin connector & add if missing
wire
missing
“E-54”
PCB component
Turn switch to OFF position, then turn switch back to ON;
failure
if “E-54” persists, have PCB replaced
“E-70A”
Fan switch jumper
Have jumper wire checked on 12 pin connect to panel
missing
“E-70B”
MV jumper missing
Have jumper wire checked on connectors to panel
“E-92”
24 VAC fuse
24 VAC fuse on I/O board open; check for shorted
on I/O open
component in 24-volt circuit (i.e.., hi limit, drain switch,
air
switch)