5-2. ERROR CODES
In the event of a control system failure, the digital
display will show an "Error Message." These
messages are coded: “E4”, “E5”, “E6”, “E10”,
“E15”, “E20”, “E-31”, “E41”, “E46”, “E54”,
E-70-A & B and “E92”. A constant tone is heard
when an error code is displayed, and to silence this
tone, press any button.
DISPLAY
CAUSE PANEL
BOARD
CORRECTION
“E-4”
Control board
Turn switch to OFF position, then turn switch back to ON.
overheating
if display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstructions
“E-5”
Shortening
Turn switch to OFF position, then turn switch back to ON;
overheating
if display shows “E-5”, the heating circuits and temperature
probe should be checked
“E-6 A”
Temperature
Turn switch to OFF position, then turn switch back to ON;
probe open
if display shows “E-6”, check the temperature probe;
to replace, refer to Technical Manual
“E-6 B”
Temperature
Turn switch to OFF position, then turn switch back to ON;
probe shorted
if display shows “E-6” check the temperature probe;
to replace, refer to Technical Manual
“E-10”
High limit
Reset the high limit by manually pushing up on the reset
button; if high limit does not reset, high limit must be
replaced;
refer
to
Technical
Manual
“E-15”
Drain switch
Close drain, using the drain valve handle; if display still
failure
shows “E-15”, check the drain microswitch; refer to
Technical
Manual
“E-41”,
Programming
Turn switch to OFF, then back to ON; if display shows any
“E-46”
failure
of the error codes, try to reinitialize the control (Special
Program Section) if error code persists, replace the control
board; refer to Technical Manual