beautypg.com

HP NetVectra N20 User Manual

Page 38

background image

Part Number
Printed in

50%

D8041-90001

Paper not bleached with chlorine

Error Messages

Recommended Action

C:DRIVE ERROR

Check hard disk type in Setup.

C:DRIVE FAILURE

Replace hard disk.

CH-2 TIME ERROR

Replace system board.

CMOS CHECKSUM ERROR

Run Setup, replace battery if error persists.

CMOS SETTINGS WRONG/CMOS DISPLAYTIME WRONG

CMOS CHECKSUM BAD

CMOS SYSTEM OPTIONS NOT SET

CMOS TIME AND DATE NOT SET

Reboot, then set time and date in Setup

DISK BOOT FAILURE, INSERT SYSTEM DISK AND PRESS ENTER

Insert system disk in

A:/

and press

Enter

. When booting from hard disk, check hard disk controller installation and

cables.

NON SYSTEM DISK OR DISK ERROR

DISK DRIVES OR TYPES MISMATCH ERROR - RUN SETUP CMOS Check drive type in Setup. Change jumper setting if necessary.
DISPLAY SWITCH IS SET INCORRECTLY

Check video setting in Setup.

DISPLAY TYPE HAS CHANGED SINCE LAST BOOT

Check video setting in Setup.

ERROR ENCOUNTERED INITIALIZING HARD DISK DRIVE/ ERROR
INITIALIZING HARD DISK CONTROLLER

Check hard disk controller installation, cables and jumper configuration. Check disk type in Setup.

HDD CONTROLLER FAILURE

FLOPPY DISK CNTRLR ERROR/ NO CNTRLR ERROR/ NO CNTRLR
PRESENT

Check FDD controller installation. If no FDD is installed, run Setup and disable floppy drive.

FDD CONTROLLER FAILURE

KEYBOARD ERROR/ NO KEYBOARD PRESENT

Check keyboard is correctly connected. Make sure no keys are pressed during boot.

KB/ INTERFACE ERROR

Check keyboard is correctly connected.

PS/2 MOUSE ERROR

Check mouse is correctly connected.

MEMORY SIZE HAS CHANGED SINCE LAST BOOT

Check memory size in Setup.

MEMORY VERIFY AT...

Use specified location to locate bad memory module.

MEMORY PARITY ERROR AT...

I/O CARD PARITY ERROR AT...

Use specified location to locate expansion card failure.

PRESS A KEY TO REBOOT

An error has occurred, press any key to reboot.

PRESS F1 TO DISABLE NMI, F2 TO REBOOT

BIOS detects NMI (Non-Maskable Interrupt). Press

F2

to reboot or

F1

to disable NMI.

RAM- CHECKING FOR SEGMENT...

Change bad RAM module.

SYSTEM HALTED, (CTRL-ALT-DEL) TO REBOOT

Boot attempt aborted. Press

Ctrl

+

Alt

+

Del

to reboot.

The computer beeps...

You should...

1,2 or 3 times

Reset memory DIMMs, replace it if necessary.

5 times

Reset the processor, replace it if necessary.

6 times

Change the keyboard or replace the fuse if applicable.

9 times

Replace system board.

4,7,8,10 times

Replace the system board or video controller.

drac-usr.bk : drac-bc.fb4 Page xxxii Friday, April 30, 1999 3:48 PM

This manual is related to the following products: