beautypg.com

Warning! disconnect input power before maintaining, Quick robotics light weight torch – Tweco Lightweight Quick Robotic Torch User Manual

Page 14

background image

Quick ROBOtics light weight tORch

5-10

SM-QRLTORCH

MAINTENANCE

Each Use

Visual check of torch

Consumable parts

Weekly

Visually inspect the torch

body and consumables

Visually inspect the

cables and leads.

Replace as needed

3 Months

Clean

exterior

of power supply

6 Months

Replace all

broken parts

Visually check and

use a vacuum to carefully

clean the interior

Gas and

air lines

dwg-00032

Visually inspect the Wire

feed mechanisms

Warning!

Disconnect input power before maintaining.

Maintain more often

if used under severe

conditions.

Visual check of

regulator and pressure

The torch and conductor tube assemblies have o-rings for
seals. Lubrication of these o-rings should be done periodically
and periodical inspections should be made to ensure that the
o-rings do not degrade, allowing water and or shielding gas
leaks to occur. When removing the conductor tube from the
torch assembly, be sure the single o-ring located in the bottom
of the hole remains in place.

Contact tips and nozzles should be cleaned frequently.
Spatter buildup may cause bridging between nozzle and tip.
This could cause electrical shorting between the nozzle and
work piece as well as restricting gas flow.
Regularly inspect the conductor tube, torch and cable
assembly for abrasions, cuts and undue wear. Replace or
repair any parts as needed.

SECTION 5:

MAINTENANCE