C–9

POST Error Messages

Red Power LED

flashes three times,

once every

second, followed

by a two second

pause. Beeps stop

after fifth iteration

but LEDs continue

until problem is

solved.

3

Processor not

installed (not an

indicator of bad

processor).

1. Check to see that the processor is

present.

2. Reseat the processor.

Red Power LED

flashes four times,

once every

second, followed

by a two second

pause. Beeps stop

after fifth iteration

but LEDs continue

until problem is

solved.

4

Power failure

(power supply is

overloaded).

1. Open the hood and ensure the 4 or

6-wire power supply cable is seated

into the connector on the system

board.

2. Check if a device is causing the

problem by removing ALL attached

devices (such as hard, diskette, or

optical drives, and expansion cards).

Power on the system. If the system

enters the POST, then power off and

replace one device at a time and

repeat this procedure until failure

occurs. Replace the device that is

causing the failure. Continue adding

devices one at a time to ensure all

devices are functioning properly.

3. Replace the power supply.

4. Replace the system board.

Red Power LED

flashes five times,

once every

second, followed

by a two second

pause. Beeps stop

after fifth iteration

but LEDs continue

until problem is

solved.

5

Pre-video memory

error.

Ä

To avoid damage to the DIMMs or the

system board, you must unplug the

computer power cord before

attempting to reseat, install, or remove

a DIMM module.

1. Reseat DIMMs.

2. Replace DIMMs one at a time to

isolate the faulty module.

3. Replace third-party memory with HP

memory.

4. Replace the system board.

POST Diagnostic Front Panel LEDs and Audible Codes (Continued)

Activity

Beeps

Possible Cause

Recommended Action