Avoid aiming the control at:

• Objects that change temperature rapidly, such as

heating

vents and air conditioners. These heat sources could
cause false triggering.

• Areas where

pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting daylight may
trigger the shut-off feature. Do not point other lights at the
sensor.

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

SPECIFICATIONS

Range . . . . . . . . . . . . . . . Up to 60 feet (varies with surround-

ing temperature).

Sensing Angle . . . . . . . . . Up to 110°
Electrical Load . . . . . . . . . Up to 500 Watts Maximum, Incan-

descent

Power Requirements . . . . 120 VAC, 60 Hz
Operating Modes . . . . . . . TEST, AUTO and MANUAL OVER-

RIDE

Time Delay . . . . . . . . . . . 1, 5, 10 minutes
Sensitivity . . . . . . . . . . . . Adjustable
HeathCo LLC reserves the right to discontinue products and
to change specifications at any time without incurring any
obligation to incorporate new features in products previously
sold.

The detector is less sensitive to motion directly towards it and
more sensitive to across motion.

Aim Sensor Down

for Short Coverage

Aim Sensor Higher

for Long Coverage

Walk through the coverage area

noting where you are when the
lights turn on. Move the sensor
head up, down, or sideways to
change the coverage area.

Adjust the SENSITIVITY as

needed. Too much sensitivity may
increase false triggering.

Set the amount of TIME you want

the lights to stay on after motion is
detected (1, 5, or 10 minutes).

Least Sensitive

Most Sensitive

Sensor

Motion

Motion

ON-TIME

10 5 1 TEST

MIN MAX

SENS

Bottom of Sensor

60 ft.

5 ft.

110°

Maximum Range

Maximum

Coverage Angle

NOTE: Sensor has a 1

1

/

2

minute warm up period before

it will detect motion. When first turned on or when
switching modes, wait 1

1

/

2

minutes.

Turn the SENSITIVITY (SENS) control to the mid position

and the ON-TIME control to the TEST position.