beautypg.com

Heath Zenith SL-5503 User Manual

Quartz halogen floodlight, No service parts available for this product, Bulb installation and relamping

background image

598-1138-02

❒ Attach the cover plate to the junction box (Apply silicon

caulk between cover plate and junction box for a raintight
seal). Keep the fi xture horizontal (within +/- 4°) so the bulb
inside is horizontal. If the bulb is not horizontal, the bulb
may darken or shatter and fail prematurely.

❒ Loosen the side bolt connected to the arm to aim the fi xture

up and down.

Bulb Installation and Relamping

Important: Use a clean glove or cloth when handling the
new bulb. Oil from your hand may cause the bulb to crack
when the fi xture heats up and result in premature failure.
Use isopropyl (rubbing) alcohol to clean the bulb if it is
touched with your bare hands.

❒ When relamping, turn power off and let the fi xture cool.
❒ Remove glass cover and remove the old bulb by pushing

the bulb towards the right until the left side of the bulb is
clear of the left socket.

❒ To insert the new bulb push the bulb into the right socket

so the bulb is properly seated in the sockets.

❒ Re-install the glass cover.
❒ Reconnect the power.

Quartz Halogen Floodlight

Model SL-5503 - 300 Watts
Model SL-5505 - 500 Watts

Fixture Installation Instructions

To avoid Electrical Shock:

The Heath

®

/Zenith Quart Halogen Floodlight disperses light over a wide area. It includes a halogen lamp, attaches to a

standard threaded junction box cover plate and is for use with 120 VAC.

FOR PROPER INSTALLATION AND OPERATION, PLEASE READ THESE INSTRUCTIONS CAREFULLY.

To Avoid Fire Or Burn Hazards:

• Allow fi xture to cool before touching. The bulb and the fi xture operate at high temperatures.
• Keep fi xture at least 2” from combustible materials. Do not aim at objects closer than 3 feet.
• Use a lamp that does not exceed the maximum ratings for your model.
Maximum ratings are: SL-5503 - 300 Watts; SL-5505 - 500 Watts.

WIRING FIXTURE

(Product May Vary from Illustration)

White to White

Black to Black

Fixture ground to

junction box ground.

Cover Plate

No Service Parts Available for this Product

© 2007 HeathCo LLC

598-1138-02

WARNING: Turn power off at the circuit breaker or

fuse.

• Follow all warnings listed on fi xture.
• Grounding and installations must comply with local codes

and the National Electric Code.

• This product should be mounted on a grounded junction

box and must be used with a threaded cover plate.

• Permanently mount the fi xture to a building or pole.
Fixture is designed for WALL MOUNT ONLY (see illus-

tration below).

❒ Thread aiming arm through the cover plate (not included) and

tighten the locknut. Apply silicon caulk for a raintight seal.

❒ Connect the lamp wires to the power source wiring. Secure

with wire connectors.